Page 12 of 21

WR 3M

1)Not in use = UP/DOWN Scroll Keys not depressed and no temperature drop > 41 °F.

2)STANDBY temperature must be below the Set temperature, otherwise the SETBACK function is inactive.

3)When a switching holder is connected, the soldering tool always remains at the Set temperature outside the holder.

The holder function is activated when the soldering tool is placed in the holder for the first time.

Note

Note

Reset of STANDBY and AUTO OFF modes:

without switching holder, by depressing the UP or DOWN Scroll Keys.

with switching holder, by removing the soldering tool from the holder.

Setting the Temperature Offset

The Read soldering-tip temperature can be adjusted by entering a temperature offset ± 72 °F ( ± 40 °C ).

1.Select the menu item OFFSET in Menu 1.

2.Set the OFFSET temperature value with the UP or DOWN Scroll Key.

3.Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Setting the Window Function

It is possible, starting from a Set, Locked temperature, to set a temperature range of ± 180 °F ( ± 99 °C ) with the WINDOW function. The temperature range (Window) must be Set prior to Locking the station.

To be able to use the WINDOW function, make sure the Rework Station is in the Locked mode (see "Switching the lock function on/off“ Page 10).

1.Select the menu item WINDOW in Menu 1.

2.Set the WINDOW temperature value with the UP or DOWN Scroll Key.

3.Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Switching the Temperature Display

Switching the temperature display from °F to °C or vice versa.

1.Select the temperature display °F / °C in Menu 1.

2.Set the temperature display with the UP or DOWN Scroll Key.

4.Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Limiting the Time (HAP ON) time for Hot-Air Pencil

With the HAP-Ontime for the Hot Air Pencil, hot-air flow can be limited in increments of 1, from 0 to 60 seconds. The set time is then identical for all 3 channels. Factory setting is 0 seconds ("OFF“), i.e.