WR 3M |
| Page 15 of 21 | |||
|
|
|
| requires a Station Identification (ID code) so that it can clearly be | |
|
|
|
| identified. | |
|
|
|
| 1. | Select the menu item REMOTE ID in Menu 2. |
|
|
|
| 2. | Enter an ID with the UP or DOWN Scroll Keys |
|
|
|
|
| (possible values 0 – 999). |
|
|
|
| 3. | Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) |
|
|
|
|
| or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT). |
|
| Note | Depress Radio Button ┌ 3 ┐ to exit the menu item without saving any | ||
|
|
|
| changes (EXIT). | |
|
|
|
| Factory Control Check ( FCC ) | |
|
|
|
| This function checks temperature accuracy of the Rework Station | |
|
|
|
| and allows modifications if necessary. To perform the “FCC” function, | |
|
|
|
| the soldering tip temperature must be measured using an external | |
|
|
|
| temperature measuring instrument, (WA2000) and appropriate type | |
|
|
|
| “K” temperature measuring tip. ( See Accessories List on page 18 ) | |
|
|
|
| Control Check at 212 °F / 100 °C | |
|
|
|
| 1. | Connect the type “K” thermocouple, into the external temperature |
|
|
|
|
| measuring instrument, (WA2000). |
|
|
|
| 2. | Select the menu item FCC in Menu 2. |
|
|
|
| 3. | Depress the DOWN Scroll Key. Control point 212 °F / 100 °C is |
|
|
|
| ||
|
|
|
|
| selected. |
|
|
|
|
| The soldering tip is now heated to 212 °F / 100 °C. |
|
|
|
|
| The Heater Control Indicator flashes ( ) (21) as soon as the |
|
|
|
|
| temperature is constant. |
|
|
|
| 4. | Compare the temperatures indicated by the meter with the |
|
|
|
|
| indications in the display. |
|
|
|
| 5. | Use the UP or DOWN Scroll Key to set the difference between the |
|
|
|
|
| value indicated on the external meter and the value indicated on |
|
|
|
|
| the Rework Station, (shown in small script in lower part of the |
|
|
|
|
| display). Maximum temperature adjustment: ± 72 °F (± 40 °C). |
|
|
|
|
| Example: |
|
|
|
|
| Display 212 °F, external meter 210 °F: setting S 2 |
|
| Note |
| Display 212 °F, external meter 214 °F: setting T 2 | |
|
| Depress Radio Button ┌ 3 ┐ to exit the menu item without saving | |||
|
|
|
| changes (EXIT). | |
|
|
|
| 6. | Depress Radio Button ┌ 2 ┐ (Set) to confirm the value. |
|
|
|
|
| The temperature deviation is now reset to 0. Factory Control |
|
|
|
|
| Check at 212 °F / 100 °C is now complete. |
|
|
|
| 7. | Exit Menu 2 by depressing Radio Button ┌ 3 ┐ twice. |
Control Check at 842 °F / 450 °C
1. Connect the type “K” thermocouple, into the external temperature measuring instrument, (WA2000).