| t r o u b l e s h o o t i n g | |
|
|
|
|
|
|
|
|
|
|
CombiTouch ERROR CODES |
|
| ||
|
|
|
|
|
|
|
|
|
|
Error | Error Call Out in Display | Description of Error | Possible Cause |
|
Code |
|
|
|
|
|
|
|
|
|
E34 | Steam Generator Drain | Water level in steam | — Scale build up inside the steam generator |
|
| Pump Fault | generator does not drop | drain pump. |
|
|
| during cleaning program | — Scale build up inside the steam generator affecting |
|
|
|
| water level probes. |
|
|
|
| — Generator drain pump is faulty. |
|
|
|
| — Connection issue at drain pump. |
|
|
|
| — No output to pump from relay board. |
|
|
|
|
|
|
E36 | Steam Temperature High | Oven cavity temperature is | — Water supply is shut off. |
|
|
| too high when operating in | — Low water pressure. |
|
|
| a steam mode or cleaning | — Wiring or connection issue. |
|
|
| program | — Water injection pipe obstructed. |
|
|
|
| — Water fl ow control valve plugged or defective. |
|
|
|
| — Dual solenoid valve |
|
|
|
| — No output to solenoid valve form relay board. |
|
|
|
|
|
|
E51 | No Water In Boiler | Water inside steam generator | — Water supply is shut off. |
|
|
| does not reach low water | — Low water pressure. |
|
|
| level | — Generator drain cap missing or loose. |
|
|
|
| — Generator drain pump is not sealing. |
|
|
|
| — Generator drain pump elbow leaking. |
|
|
|
| — Faulty or scaled water level probe. |
|
|
|
| — Faulty or plugged dual solenoid valve assembly. |
|
|
|
| — Wiring or connection issue. |
|
|
|
| — No output to dual solenoid from relay board. |
|
|
|
|
|
|
E53 | Fan Motor High | Fan motor too hot | — Exhaust hood is not operating properly. |
|
| Temperature |
| — Check LED fl ashes on the Motor Control. |
|
|
|
| — See Motor Control Error Code list. |
|
|
|
| — Connection Issue on Hall Effect sensor. |
|
|
|
| — Fan wheel is not operating. |
|
|
|
| — Hall sensor does not detect motor rotation. |
|
|
|
|
|
|
E54 | Fan Motor 2 High | 20•20 lower fan motor too hot | — Exhaust hood is not operating properly. |
|
| Temperature |
| — Check LED fl ashes on the Motor Control. |
|
|
|
| — See Motor Control Error Code list. |
|
|
|
| — Connection Issue on Hall Effect sensor. |
|
|
|
| — Fan wheel is not operating. |
|
|
|
| — Hall sensor does not detect motor rotation. |
|
|
|
|
|
|
E55 | Vent Not Open | Browning valve does not open | — Alignment issue between motor cam and vent |
|
|
|
| motor safety switch (micro switch). |
|
|
|
| — Fault vent valve (motor). |
|
|
|
| — Fault vent valve safety switch (micro switch). |
|
|
|
| — Wiring or connection problem. |
|
|
|
|
|
|
(Continued on next page)
46