Cornelius 322 manual Sanitizing And Cleaning Procedure

Models: 322

1 32
Download 32 pages 61.15 Kb
Page 12
Image 12
SANITIZING AND CLEANING PROCEDURE

Re--check per above procedure.

SANITIZING AND CLEANING PROCEDURE

1.Remove front panel to gain access to the on--off clean switch.

2.Push switch to “Clean”and allow the ice on the evaporator to release or melt away.

ELECTRICAL BOX

SWITCH, DUMPManual background

SWITCH, ON/OFF/CLEAN

WATER PUMPManual backgroundManual backgroundManual backgroundManual backgroundManual background

ILL063

3.Remove ice from storage bin.

4.If lime scale is present add 2 oz. of “Lime--A--Way”or “Calgon NickelSafe Ice Machine Cleaner”directly into water reservoir. Circulate for not longer than 10 minutes. Depress dump valve switch on side of control box and allow cleaner or sanitizer to drain away. Allow float valve to fill reservoir with clean, fresh water. Circu- late for approximately 1 minute. Depress dump valve switch and allow water to drain away. Repeat three times.

CAUTION: All ice machine cleaner must be flushed out of the system before the sanitizing solution is used in Step 5. The reaction of the two chemical can cause hazardous gases to be generated.

5.Pour 1/4 oz. of household bleach into the water reservoir and circulate for 10 minutes to sanitize the circu- lating water system including the evaporator, pump, distributor and all interconnecting vinyl tubing. Depress dump valve switch on side of control box and allow cleaner or sanitizer to drain away. Allow float valve to fill reservoir with clean, fresh water. Circulate for approximately 1 minute. Depress dump valve switch and al- low water to drain away. Repeat three times.

6.Mix sanitizing solution of 1/2 oz. household bleach to one gallon of water. This mixture will provide 200 ppm chlorine. Using a non--metallic bristle brush, scrub the following:

A.Inside surface of the ice bin including top and door.

B.Inside surface of the ice maker to include evaporator section in the ice machine including the top, front panel and evaporator splash curtain.

C.Make sure splash curtain is correctly positioned.

7.Depress dump valve switch and allow cleaner to drain away. Allow float valve to fill reservoir with clean, fresh water. Circulate for approximately 1 minute. Depress dump valve switch and allow water to drain away. Repeat three times.

8.Push switch from “clean”to “on”position.

9.Replace front panel.

3/17/95

9

166240008

Page 12
Image 12
Cornelius 322 manual Sanitizing And Cleaning Procedure