Cycle time (CT) = freeze time plus harvest time, in minutes and seconds. 1440 divided by CT = number of cycles per 24 hours.
Measure weight of ice from one cycle in pounds and fractions of a pound.
Example: Weight/cycle x cycles/day = total production/24 hrs. Compare to the production tables
* If water cooled, be certain water regulator valve is set to maintain 225/235 PSI head pressure.
|
| Water |
|
|
| |
|
| Dump |
|
|
| |
|
| Valve |
|
|
| |
|
|
|
|
|
| |
RH Evap. Switch | YL |
|
|
|
|
|
|
|
|
|
|
| |
| RH Evap. | Contactor | 7 | 8 |
| |
|
|
|
| |||
|
|
|
|
|
| |
|
|
| Water | 5 | 6 |
|
|
|
|
|
|
| |
LH Evap. Switch | YL |
| Pump | 3 | 4 |
|
|
|
| ||||
|
| 2 |
| |||
|
| 1 |
| |||
|
|
|
|
| ||
| LH Evap. |
|
|
|
| |
|
|
|
|
|
| |
Condenser Sensor |
|
| GR | Hot Gas |
|
|
|
|
|
|
|
| |
| Condenser |
|
|
|
| |
White | plug |
|
|
| 230v | |
Suction Line Sensor |
|
|
|
|
| |
|
|
|
|
|
| |
| Suction plug | Fan |
| Voltage | neutral | |
Brown |
|
|
|
| Selector | |
|
|
|
|
| ||
|
|
|
| Switch |
| |
| Test | RD |
|
|
| 115v |
| Plug | GR |
|
| ||
|
|
|
| |||
|
|
|
|
| ||
|
| Error |
|
|
|
|
| Options |
|
|
|
|
|
| Plug | Adjustable | Ice |
|
|
|
|
|
|
|
| ||
|
| Thickness Pot. | Transformer |
|
| |
|
|
|
|
|
| |
| Micro Processor |
|
|
|
|
|
| Stacking |
|
|
|
|
|
| Cable |
|
|
|
|
|
| Plug |
| Manual |
|
|
|
To Stacked Unit |
|
| Harvest |
|
|
|
|
| Switch |
|
|
| |
(if required) |
|
|
|
|
| |
|
|
|
|
|
|
LED INDICATORS
The LEDs are board circuit indicators. If the LED in the functional board circuit is complete, check component.
Example: Contactor does not energize and LED is “ON”, board circuit is OK. Check contactor, coil, leads, & connections.
Yellow:
SEvaporator switch(s) (proximity) Green:
SWater dump valve
SCompressor contactor S Water Pump
S Hot Gas Valve
S Condenser Fan (cycles on & off with fan) Red:
Error in system operation. Product shut down.
166240008 | 16 | 3/17/95 |