Cornelius 322 manual Led Indicators

Models: 322

1 32
Download 32 pages 61.15 Kb
Page 19
Image 19
LED INDICATORS

Cycle time (CT) = freeze time plus harvest time, in minutes and seconds. 1440 divided by CT = number of cycles per 24 hours.

Measure weight of ice from one cycle in pounds and fractions of a pound.

Example: Weight/cycle x cycles/day = total production/24 hrs. Compare to the production tables

* If water cooled, be certain water regulator valve is set to maintain 225/235 PSI head pressure.

 

 

D-15

Water

 

 

 

 

D-13

 

Dump

 

 

 

 

 

Valve

 

 

 

 

 

 

 

 

 

RH Evap. Switch

YL

 

 

 

 

 

 

 

 

 

 

 

 

RH Evap.

D-14

Contactor

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

5

6

 

 

 

 

 

 

 

LH Evap. Switch

YL

 

Pump

3

4

 

D-10

D-12

 

 

 

 

 

2

 

 

 

1

 

 

 

 

 

 

 

LH Evap.

 

 

 

 

 

 

 

 

 

 

Condenser Sensor

 

 

GR

Hot Gas

 

 

 

 

 

 

 

 

 

Condenser

 

D-11

 

 

 

White

plug

 

 

 

230v

Suction Line Sensor

 

 

 

 

 

 

 

 

 

 

 

 

Suction plug

Fan

 

Voltage

neutral

Brown

 

 

 

 

Selector

 

 

 

 

 

 

 

 

D-6

 

Switch

 

 

Test

RD

 

 

 

115v

 

Plug

GR

 

 

 

 

 

 

 

 

D-5

 

 

 

 

 

Error

 

 

 

 

 

Options

 

 

 

 

 

 

Plug

Adjustable

Ice

 

 

 

 

 

 

 

 

 

 

Thickness Pot.

Transformer

 

 

 

 

 

 

 

 

 

Micro Processor

 

 

 

 

 

 

Stacking

 

 

 

 

 

 

Cable

 

 

 

 

 

 

Plug

 

Manual

 

 

 

To Stacked Unit

 

 

Harvest

 

 

 

 

 

Switch

 

 

 

(if required)

 

 

 

 

 

 

 

 

 

 

 

LED INDICATORS

The LEDs are board circuit indicators. If the LED in the functional board circuit is complete, check component.

Example: Contactor does not energize and LED is “ON”, board circuit is OK. Check contactor, coil, leads, & connections.

Yellow:

SEvaporator switch(s) (proximity) Green:

SWater dump valve

SCompressor contactor S Water Pump

S Hot Gas Valve

S Condenser Fan (cycles on & off with fan) Red:

Error in system operation. Product shut down.

166240008

16

3/17/95

Page 19
Image 19
Cornelius 322 manual Led Indicators