NOTE: TAKE CARE NOT TO KINK OR COLLAPSE VINYL TUBING.
VENT
DRAIN WC
CONDENSER
DRAIN
CONDENSATION
BIN
DRAIN
POWER CORD (322 UNIT ONLY)
STRAINER WATER
SERVICE VALVES
50 PSI MAX. WATER PRESSURE
WATER SUPPLY ICE MAKING
WATER SUPPLY WC CONDENS-
ER
DUMP VALVE
DRAIN
DRAIN
PIPE
VENT
OPEN TRAPPED OR VENTED
DRAIN
TYPICAL INSTALLATION: ALL ELECTRICAL & PLUMBING | ill018 |
MUST BE DONE PER LOCAL CODES. |
|
DRAIN
Provide a suitable trapped open drain as close as possible to the area where the ice maker is going to be installed. This may be an existing floor or a
An additional separate drain line will be required for water cooled units from the outlet of the condenser coil to the drain. Run all gravity drain lines with a good fall to the open drain.
All Plumbing Must Be Installed In Accordance With Local Codes.
NOTE: In some cases it may be necessary to insulate the water supply line and drain line. Condensate dripping to the floor can cause serious staining of carpets or hardwoods.
DRAIN CONNECTION INSTALLATION INSTRUCTIONS.
Taking care not to kink or collapse vinyl tubing at any point, route tubes to any open, trapped or vented floor drain. Run tubing to drain separately. Do not tee any drain hoses together. Add drain tubing required to reach floor drain.
WATER LEVEL RESERVOIR
The Float Valve is mounted in a fixed position thru it’s mounting bracket to maintain the proper water level in the water reservoir. For the 300 & 322 series units the bracket is mounted thru the bottom hole of the bracket.
166240008 | 6 | 3/17/95 |