Diagram 2
MAKE ELECTRICAL POWER SUPPLY CONNECTION
Requirements: 115V/60 Hz 1 ph., 230V/60 Hz. 1 ph., or 220V/50 Hz. 1 ph when used.
Refer to serial plate for minimum circuit ampacity and maximum time delay fuse size.
All wiring must conform to national and local electrical codes.
MAKE PLUMBING CONNECTIONS
Water supply
The water inlet connection to the unit is a 3/8”male flare connection located at the rear of the ice machine.
WARNING: If the water pressure exceeds 50 pounds, a water pressure regulator should be installed in the water inlet line between the water
Install a reducer fitting on the
For water cooled units
Two water inlet connections are provided. One for the ice making (evaporator) section which is located on the back of the machine and is a 3/8”flared connection. The other is for the water cooled condenser.
The reason for the separate water inlet connections is that some installations use a water tower for cooling the water used in the water cooled condenser and some installations use treated water (filtered) for the ice making inlet water connections. Be sure to install water line (incoming) to the 3/8”male flare connection on the back of the unit that supplies water to the water regulating valve inside. The setting of the water regulating valve from the factory should be 200 pounds for
3/17/95 | 5 | 166240008 |