•If the heat level is equal to 1 when the thermostat calls for heat the
•The stove will operate at the selected Heat Level until such time as the thermostat stops calling for heat. The
CHANGE HEAT LEVEL (thermostat active)
•When the homeowner changes the control board heat level setting, while the thermostat is active (calling for heat,) the new setting becomes the new thermostat (call for heat) setting. The stove will move to that heat setting anytime the thermostat calls for heat. Otherwise, when the thermostat no longer calls for heat, the control board sets the stove to Heat #1.
•If the operator changes the heat level to 1 while the thermostat is calling for heat, it will become the new Thermostat Heat Level. But because this is the same setting as when the thermostat stops calling for heat, the operator will get no indication that the thermostat is in control of the stove.
CHANGE HEAT LEVEL (thermostat inactive)
•If the operator makes a change to the heat level while the stove is inactive, the stove will move to that level. The next time the thermostat calls for heat, the most recently programmed heat level will become the Thermostat Heat Level and the stove will operate at that point until the thermostat no longer calls for heat.
FIGURE 10: CROSSFIRE COMBUSTION FRESH AIR CONTROL
COMBUSTION FRESH AIR CONTROL
Combustion fresh air can be controlled on the Crossfire. This optional control assists in optimizing the burn rate of the fuel. All air entering the firebox is controlled with this fresh air control system. A control knob is located above the electronic control. This black knob can be turned to open and close the baffle as shown in FIGURE 10. By opening or closing this baffle the amount of fresh air allowed into the combustion chamber can be controlled. This air control should allow the homeowner to adjust for any variation in fuel to ensure an efficient burn. If the fresh air is connected to a pipe leading outside the house, the fresh air control should be kept in the closed condition to minimize air infiltration into the home when the Crossfire stove is not in use.
Version 2.0e | 23 |