APPENDIX C: TECHNICAL SPECIFICATIONS
Fuel Type: | #2 Yellow Shelled Corn Fuel | Wood Pellet Fuel | ||
| Moisture Content: 14% or less (12% preferred) | A.P.F.I. residential fuel | ||
| Heat Content: 10,000 Btu/lb* | Heat Content: 8200 BTU/lb | ||
| Ash Content: 3% maximum | Ash Content: 1% max | ||
| 5.9 lbs/hour maximum feed rate | Bulk Density: | 40 lb./cubic ft. min | |
|
|
| Moisture Content: 8% max | |
|
|
| Size: 1/4” to 3/8” diameter | |
|
|
| 1.5” long max | |
|
|
| Fines: 1% max through 1/8th screen | |
Hopper Size: |
| 72 pounds corn or 55 pounds wood pellets |
| |
Flue Size: |
| 4” recommended. If less than 10 feet use of 3 inch pipe is approved. | ||
Flue Type: |
| PL double wall vent with stainless steel inner liner |
| |
Air Inlet: |
| 3 inch by .15 inch walled steel pipe |
|
|
Auger Type: |
| 1 1/8” cup Auger Feed System |
|
|
Controls: |
| Country Flame |
| |
Electrical: |
| 120 Volts, 2.4 Amp, 60 Hz |
|
|
Measurements: | CROSSFIRE HEIGHT (at front) |
| 22.5” | |
|
| CROSSFIRE DEPTH (from shroud) | 14.0” | |
|
| CROSSFIRE WIDTH (rear) |
| 26.0” |
|
| CROSSFIRE WIDTH (at shroud mount) | 25.5” | |
Weight : |
| STOVE WEIGHT |
| 220 POUNDS |
Clearances: |
| UNIT TO SIDEWALL |
| 7” |
|
| UNIT TO SIDE TRIM |
| 7” |
|
| UNIT TOP TO SIDE TRIM |
| 9.25” |
|
| UNIT TOP TO MANTLE |
| 9.25” |
|
| HEARTH FLOOR TO MANTLE |
| 32” |
|
| NONCOMBUSTIBLE FLOOR PROTECTION (front) | 6” | |
|
| NONCOMBUSTIBLE FLOOR PROTECTION (sides) | 6” | |
Shroud Measurements: |
|
| ||
|
| SHROUD WIDTH (standard) |
| 42.0” |
|
| SHROUD HEIGHT (standard) |
| 30.0” |
|
| SHROUD WIDTH (oversized) |
| 48.0” |
|
| SHROUD HEIGHT (oversized) |
| 32.5“ |
*BTU/lb can vary depending on the moisture content of the corn.
Version 2.0e | 47 |