the door glass. Removal of these glass retaining clips can be accomplished with household tools. Order the necessary replacement screws or glass clips when ordering glass to ensure worn parts are replaced.
Euro Kera | |
Manufacturer | |
Window Type |
KERA LITE®
CAUTION: Do not attempt to clean hot glass. Do not abuse, strike, slam shut, or operate the Harvester stove with any broken glass in the appliance.
GASKET REPLACEMENTRemove the doors from the unit. Place the doors, face down on a protective surface to ensure no marring or scratching occurs during gasket replacement. To replace the Thermoglass™ knitted rope and tape gasket, first remove all of the old material and gasket cement. Use a putty knife or other sharp instrument to assist in removal. Use caution to prevent injury when removing old material. It is important to ensure the doorframe area is totally clean before installing the new gasket cement and material. The gasket must fit tight against the door frame in order to ensure a proper airtight seal when the stove is being operated. Apply gasket cement to the gasket channel per instructions provided with the gasket kit. Once the cement has been properly applied, install the new gasket. Both gasket and gasket cement are available from your authorized Country Flame dealer. The following table defines the gasket material used in the Harvester stove:
Gasket | Length | Quantity | Dimensions |
Around glass | 4.25 feet each | 2 | ¾” wide by 1/16” thick tape |
Doorframe | 5 feet each | 2 | 3/8” rope, high density |
Ash drawer | 30 inches | 1 | ½” wide by 1/8” thick tape |
Version 2.0b | 40 |