APPENDIX C: TECHNICAL SPECIFICATIONS
Fuel Type: | #2 Yellow Shelled Corn Fuel | Wood Pellet Fuel | ||
| Moisture Content: 14% or less (12% preferred) | A.P.F.I. residential fuel | ||
| Heat Content: 10,000 Btu/lb* | Heat Content: 8200 BTU/lb | ||
| Ash Content: 3% maximum | Ash Content: 1% max | ||
|
|
| Bulk Density: 40 lb./cubic ft. min | |
|
|
| Moisture Content: 8% max | |
|
|
| Size: | 1/4” to 3/8” diameter |
|
|
|
| 1.5” long max |
|
|
| Fines: 1% max through 1/8th screen | |
Hopper Size: |
| 75 pounds corn or 55 pounds wood pellets |
| |
Flue Size: |
| 3” or 4” – dependent on the chimney height |
| |
Flue Type: |
| Type L or PL (double wall vent) |
|
|
|
| Type L or PL (single wall stainless steel liner) | ||
Air Inlet: |
| 1 1/2” Sch 40 Black Iron pipe |
|
|
Auger Type: |
| 1 1/8” cup Auger Feed System |
|
|
Controls: |
| Electronic Integrated Feed Rate/Blower Speed Controls | ||
Electrical: |
| 120 Volts, 3 Amperes, and 60 Hz |
|
|
Measurements: | UNIT BODY HEIGHT |
| 22.75” | |
|
| HEIGHT ON PEDESTAL |
| 33.75” |
|
| HEIGHT ON LEGS |
| 31.25” |
|
| UNIT WIDTH (REAR) |
| 25.5” |
|
| WIDTH AT WIDEST POINT |
| 30.75” |
|
| UNIT DEPTH |
| 24.5” |
Weight : |
| STOVE WEIGHT |
| 400 |
Clearances: |
| UNIT TO SIDEWALL |
| 2” |
|
| UNIT TO BACKWALL |
| 1” |
|
| UNIT CORNER TO DIAGONAL WALL | 1” | |
|
| TOP TO COMBUSTIBLE |
| 8” |
|
| TOP TO CEILING (Alcove) |
| 8” |
Shroud Measurements:
*BTU/lb can vary depending on the moisture content of the corn.
Version 2.0b | 46 |