CY24272

Table 6. Command Code 80h[5]

Bit

Register

POD

Type

Description

 

7

Reserved

0

RW

Reserved (no internal function)

 

 

 

 

 

 

 

6

MULT2

0

RW

PLL Multiplier Select (reference Table 3 on page 3)

 

 

 

 

 

 

 

5

MULT1

0

RW

 

 

 

 

 

 

 

 

4

MULT0

1

RW

 

 

 

 

 

 

 

 

3

RegA

1

RW

Clock 0 Output Select

 

 

 

 

 

 

 

2

RegB

1

RW

Clock 1 Output Select

 

 

 

 

 

 

 

1

RegC

1

RW

Clock 2 Output Select

 

 

 

 

 

 

 

0

RegD

1

RW

Clock 3 Output Select

 

 

 

 

 

 

 

Table 7. Command Code 81h[5]

 

 

 

Bit

Register

POD

Type

Description

 

7

Reserved

0

RW

Reserved (no internal function)

 

 

 

 

 

 

 

6

Reserved

0

RW

 

 

 

 

 

 

 

 

5

Reserved

0

RW

 

 

 

 

 

 

 

 

4

Reserved

0

RW

 

 

3

Reserved

1

RW

Reserved (must be set to ‘1’ for proper operation)

 

2

REFSEL

0

RW

Reference Frequency Select (reference Table 3 on page 3)

 

1

Reserved

0

RW

Reserved (must be set to ‘0’ for proper operation)

 

0

RegTest

0

RW

Reserved (must be set to ‘0’ for proper operation)

 

 

 

 

 

 

 

Table 8. Command Code 82h[5]

 

 

 

Bit

Register

POD

Type

Description

 

7

Device

?

RO

Contact factory for Device Revision Number information.

 

 

Revision

 

 

 

 

6

?

RO

 

 

Number

 

 

 

 

 

 

 

5

?

RO

 

 

 

 

 

 

 

 

 

 

 

4

 

?

RO

 

 

 

 

 

 

 

 

3

 

?

RO

 

 

2

Vendor ID

0

RO

Rambus assigned Vendor ID Code

 

 

 

 

 

 

 

1

 

1

RO

 

 

 

 

 

 

 

 

0

 

0

RO

 

 

 

 

 

 

 

 

Note

5. RW = Read and Write, RO = Read Only, POD = Power on default. See Table 3 on page 3 for PLL multipliers and Table 5 on page 4 for clock output selections.