CY7C1146V18, CY7C1157V18

CY7C1148V18, CY7C1150V18

TAP Controller Block Diagram

Figure 3. Tap Controller Block Diagram

TDI

 

 

 

 

 

0

 

 

 

 

 

Bypass Register

 

 

Selection

 

 

2

1

0

Selection

TDO

Circuitry

Instruction Register

 

 

Circuitry

 

 

 

 

 

 

31

30 29 . .

2

1

0

 

 

 

Identification Register

 

 

 

106

. .

. .

2

1

0

 

 

 

Boundary Scan Register

 

 

 

TCK TMS

TAP Controller

TAP Electrical Characteristics

The Tap Electrical Characteristics table over the operating range follows. [11, 12, 13]

Parameter

Description

Test Conditions

Min

Max

Unit

VOH1

Output HIGH Voltage

IOH = −2.0 mA

1.4

 

V

VOH2

Output HIGH Voltage

IOH = −100 μA

1.6

 

V

VOL1

Output LOW Voltage

IOL = 2.0 mA

 

0.4

V

VOL2

Output LOW Voltage

IOL = 100 μA

 

0.2

V

VIH

Input HIGH Voltage

 

0.65 VDD

VDD + 0.3

V

VIL

Input LOW Voltage

 

–0.3

0.35 VDD

V

IX

Input and Output Load Current

GND ≤ VI ≤ VDD

−5

5

μA

Notes

11.These characteristics pertain to the TAP inputs (TMS, TCK, TDI, and TDO). Parallel load levels are specified in the Electrical Characteristics Table.

12.Overshoot: VIH(AC) < VDDQ + 0.35V (Pulse width less than tCYC/2), Undershoot: VIL(AC) >0.3V (Pulse width less than tCYC/2).

13.All voltage referenced to ground.

Document Number: 001-06621 Rev. *D

Page 15 of 27

[+] Feedback

Page 15
Image 15
Cypress CY7C1157V18, CY7C1148V18, CY7C1146V18 TAP Controller Block Diagram, TAP Electrical Characteristics, Gnd ≤ Vi ≤ Vdd