CY7C1146V18, CY7C1157V18 CY7C1148V18, CY7C1150V18

Maximum Ratings

Exceeding maximum ratings may shorten the useful life of the device. These user guidelines are not tested.

Storage Temperature ................................ –65°C to + 150°C

Ambient Temperature with Power Applied –55°C to + 125°C

Supply Voltage on VDD Relative to GND

–0.5V to + 2.9V

Supply Voltage on VDDQ Relative to GND

–0.5V to + VDD

DC Applied to Outputs in High-Z

–0.5V to VDDQ + 0.3V

DC Input Voltage[12]

–0.5V to V + 0.3V

 

 

DD

Current into Outputs (LOW)

20 mA

Static Discharge Voltage (MIL-STD-883, M 3015)....

>2001V

Latch up Current

>200 mA

Operating Range

 

Ambient

VDD[16]

VDDQ[16]

Range

Temperature

Commercial

0°C to +70°C

1.8 ± 0.1V

1.4V to

 

 

 

VDD

Industrial

–40°C to +85°C

 

Electrical Characteristics

The DC Electrical Characteristics over the operating range follows. [13]

Parameter

Description

 

 

 

Test Conditions

Min

Typ

Max

Unit

VDD

Power Supply Voltage

 

 

 

 

 

 

 

 

 

1.7

1.8

1.9

V

VDDQ

IO Supply Voltage

 

 

 

 

 

 

 

 

 

1.4

1.5

VDD

V

VOH

Output HIGH Voltage

Note 17

 

 

 

 

 

 

VDDQ/2 – 0.12

 

VDDQ/2 + 0.12

V

VOL

Output LOW Voltage

Note 18

 

 

 

 

 

 

VDDQ/2 – 0.12

 

VDDQ/2 + 0.12

V

VOH(LOW)

Output HIGH Voltage

IOH = –0.1 mA, Nominal Impedance

VDDQ – 0.2

 

VDDQ

V

VOL(LOW)

Output LOW Voltage

IOL = 0.1 mA, Nominal Impedance

VSS

 

0.2

V

VIH

Input HIGH Voltage

 

 

 

 

 

 

 

 

 

VREF + 0.1

 

VDDQ + 0.15

V

VIL

Input LOW Voltage

 

 

 

 

 

 

 

 

 

–0.15

 

VREF – 0.1

V

IX

Input Leakage Current

GND ≤ VI ≤ VDDQ

 

 

 

–2

 

2

μA

IOZ

Output Leakage Current

GND ≤ VI ≤ VDDQ, Output Disabled

–2

 

2

μA

VREF

Input Reference Voltage[19]

Typical Value = 0.75V

 

 

0.68

0.75

0.95

V

IDD [20]

VDD Operating Supply

VDD = Max, IOUT = 0 mA,

 

300 MHz

 

 

850

mA

 

 

f = fmax = 1/tCYC

 

 

 

 

 

 

 

 

 

 

 

 

 

333 MHz

 

 

920

mA

 

 

 

 

 

 

 

 

 

 

375 MHz

 

 

1020

mA

 

 

 

 

 

 

 

 

 

 

ISB1

Automatic Power Down

Max VDD, Both Ports

 

 

300 MHz

 

 

250

mA

 

Current

Deselected, VIN

≥ VIH or

 

 

 

 

 

 

 

 

333 MHz

 

 

260

mA

 

 

V

 

≤ V

f = f

 

= 1/t

 

,

 

 

 

 

 

IN

IL

 

max

 

CYC

 

 

 

 

 

 

 

 

Inputs Static

 

 

 

 

375 MHz

 

 

290

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Input Requirements

Over the operating range[12]

Parameter

Description

Test Conditions

Min

Typ

Max

Unit

VIH

Input HIGH Voltage

 

VREF + 0.2

VDDQ + 0.24

V

VIL

Input LOW Voltage

 

–0.24

VREF – 0.2

V

Notes

16.Power up: Is based on a linear ramp from 0V to VDD(min) within 200 ms. During this time VIH < VDD and VDDQ < VDD.

17.Outputs are impedance controlled. IOH = –(VDDQ/2)/(RQ/5) for values of 175Ω < RQ < 350Ω.

18.Outputs are impedance controlled. IOL = (VDDQ/2)/(RQ/5) for values of 175Ω < RQ < 350Ω.

19.VREF (min) = 0.68V or 0.46 VDDQ, whichever is larger, VREF (max) = 0.95V or 0.54 VDDQ, whichever is smaller.

20.The operation current is calculated with 50% read cycle and 50% write cycle.