CY7C1146V18, CY7C1157V18
CY7C1148V18, CY7C1150V18
Document Number: 001-06621 Rev. *D Page 20 of 27
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. These user guidelines are not tested.
Storage Temperature ................................–65°C to + 150°C
Ambient Temperature with Power Applied –55°C to + 125°C
Supply Voltage on VDD Relative to GND.......–0.5V to + 2.9V
Supply Voltage on VDDQ Relative to GND.....–0.5V to + VDD
DC Applied to Outputs in High-Z......... –0.5V to VDDQ + 0.3V
DC Input Voltage[12]...............................–0.5V to VDD + 0.3V
Current into Outputs (LOW).........................................20 mA
Static Discharge Voltage (MIL-STD-883, M 3015).... >2001V
Latch up Current..................................................... >200 mA
Operating Range
Range Ambient
Temper atur e VDD[16] VDDQ[16]
Commercial 0°C to +70°C 1.8 ± 0.1V 1.4V to
VDD
Industrial –40°C to +85°C
Electrical Characteristics
The DC Electrical Characteristics over the operating range follows. [13]
Parameter Description Test Conditions Min Typ Max Unit
VDD Power Supply Voltage 1.7 1.8 1.9 V
VDDQ IO Supply Voltage 1.4 1.5 VDD V
VOH Output HIGH Voltage Note 17 VDDQ/2 – 0.12 VDDQ/2 + 0.12 V
VOL Output LOW Voltage Note 18 VDDQ/2 – 0.12 VDDQ/2 + 0.12 V
VOH(LOW) Output HIGH Voltage IOH = –0.1 mA, Nominal Impedance VDDQ – 0.2 VDDQ V
VOL(LOW) Output LOW Voltage IOL = 0.1 mA, Nominal Impedance VSS 0.2 V
VIH Input HIGH Voltage VREF + 0.1 VDDQ + 0.15 V
VIL Input LOW Voltage –0.15 VREF – 0.1 V
IXInput Leakage Current GND VI VDDQ –2 2 μA
IOZ Output Leakage Current GND VI VDDQ, Output Disabled –2 2 μA
VREF Input Reference Voltage[19] Typical Value = 0.75V 0.68 0.75 0.95 V
IDD [20] VDD Operating Supply VDD = Max, IOUT = 0 mA,
f = fmax = 1/tCYC
300 MHz 850 mA
333 MHz 920 mA
375 MHz 1020 mA
ISB1 Automatic Power Down
Current Max VDD, Both Ports
Deselected, VIN VIH or
VIN VIL f = fmax = 1/tCYC,
Inputs Static
300 MHz 250 mA
333 MHz 260 mA
375 MHz 290 mA
AC Input Requirements
Over the operating range[12]
Parameter Description Test Conditions Min Typ Max Unit
VIH Input HIGH Voltage VREF + 0.2 VDDQ + 0.24 V
VIL Input LOW Voltage –0.24 VREF – 0.2 V
Notes
16.Power up: Is based on a linear ramp from 0V to VDD(min) within 200 ms. During this time VIH < VDD and VDDQ < VDD.
17.Outputs are impedance controlled. IOH = –(VDDQ/2)/(RQ/5) for values of 175Ω < RQ < 350Ω.
18.Outputs are impedance controlled. IOL = (VDDQ/2)/(RQ/5) for values of 175Ω < RQ < 350Ω.
19.VREF (min) = 0.68V or 0.46 VDDQ, whichever is larger, VREF (max) = 0.95V or 0.54 VDDQ, whichever is smaller.
20.The operation current is calculated with 50% read cycle and 50% write cycle.
[+] Feedback [+] Feedback