Cypress CY7C1475BV33, CY7C1471BV33, CY7C1473BV33 manual TAP AC Switching Characteristics, TAP Timing

Models: CY7C1475BV33 CY7C1471BV33 CY7C1473BV33

1 32
Download 32 pages 5.35 Kb
Page 18
Image 18

CY7C1471BV33

CY7C1473BV33, CY7C1475BV33

TAP AC Switching Characteristics

Over the Operating Range[10, 11]

Parameter

Description

Min

Max

Unit

Clock

 

 

 

 

 

 

 

 

 

tTCYC

TCK Clock Cycle Time

50

 

ns

tTF

TCK Clock Frequency

 

20

MHz

tTH

TCK Clock HIGH time

20

 

ns

tTL

TCK Clock LOW time

20

 

ns

Output Times

 

 

 

 

tTDOV

TCK Clock LOW to TDO Valid

 

5

ns

tTDOX

TCK Clock LOW to TDO Invalid

0

 

ns

Setup Times

 

 

 

 

tTMSS

TMS Setup to TCK Clock Rise

5

 

ns

tTDIS

TDI Setup to TCK Clock Rise

5

 

ns

tCS

Capture Setup to TCK Rise

5

 

ns

Hold Times

 

 

 

 

 

 

 

 

 

tTMSH

TMS Hold after TCK Clock Rise

5

 

ns

tTDIH

TDI Hold after Clock Rise

5

 

ns

tCH

Capture Hold after Clock Rise

5

 

ns

TAP Timing

Figure 3. TAP Timing

1

 

2

 

 

 

 

 

 

Test Clock

 

 

 

 

 

 

 

(TCK )

 

 

tTH

 

 

 

 

 

 

 

 

 

 

 

tTM SS

 

tTM SH

 

 

 

 

 

 

 

 

 

Test M ode Select (TM S)

tTDIS tTDIH

Test Data-In (TDI)

Test Data-Out (TDO)

3

4

5

6

tTL

tCY C

 

 

tTDO V

tTDOX

DON’T CA RE

UNDEFINED

Notes

10.tCS and tCH refer to the setup and hold time requirements of latching data from the boundary scan register. 11.Test conditions are specified using the load in TAP AC Test Conditions. tR/tF = 1 ns.