Maximum Ratings

CY7C1511JV18, CY7C1526JV18 CY7C1513JV18, CY7C1515JV18

Maximum Ratings

Exceeding maximum ratings may impair the useful life of the device. These user guidelines are not tested.

Storage Temperature

–65°C to +150°C

Ambient Temperature with Power Applied

.... –10°C to +85°C

Supply Voltage on VDD Relative to GND

–0.5V to +2.9V

Supply Voltage on VDDQ Relative to GND

.......–0.5V to +VDD

DC Applied to Outputs in High-Z

–0.5V to VDDQ + 0.3V

DC Input Voltage [13]

–0.5V to V + 0.3V

 

 

DD

Current into Outputs (LOW)

 

20 mA

Static Discharge Voltage (MIL-STD-883, M. 3015)..

> 2001V

Latch-up Current

...................................................

 

> 200 mA

Operating Range

 

 

 

 

 

 

 

 

 

Ambient

VDD [17]

VDDQ [17]

Range

 

Temperature (TA)

Commercial

 

0°C to +70°C

1.8 ± 0.1V

1.4V to

 

 

 

 

VDD

Industrial

 

–40°C to +85°C

 

Electrical Characteristics

DC Electrical Characteristics

Over the Operating Range [14]

Parameter

Description

Test Conditions

 

Min

Typ

Max

Unit

VDD

Power Supply Voltage

 

 

 

1.7

1.8

1.9

V

VDDQ

IO Supply Voltage

 

 

 

1.4

1.5

VDD

V

VOH

Output HIGH Voltage

Note 18

 

VDDQ/2 – 0.12

 

VDDQ/2 + 0.12

V

VOL

Output LOW Voltage

Note 19

 

VDDQ/2 – 0.12

 

VDDQ/2 + 0.12

V

VOH(LOW)

Output HIGH Voltage

IOH = 0.1 mA, Nominal Impedance

 

VDDQ – 0.2

 

VDDQ

V

VOL(LOW)

Output LOW Voltage

IOL = 0.1 mA, Nominal Impedance

 

VSS

 

0.2

V

VIH

Input HIGH Voltage

 

 

 

VREF + 0.1

 

VDDQ + 0.3

V

VIL

Input LOW Voltage

 

 

 

–0.3

 

VREF – 0.1

V

IX

Input Leakage Current

GND VI VDDQ

 

5

 

5

μA

IOZ

Output Leakage Current

GND VI VDDQ, Output Disabled

 

5

 

5

μA

VREF

Input Reference Voltage [20]

Typical Value = 0.75V

 

0.68

0.75

0.95

V

IDD

VDD Operating Supply

VDD = Max,

 

(x8)

 

 

1090

mA

 

 

IOUT = 0 mA,

 

 

 

 

 

 

 

 

 

(x9)

 

 

1090

 

 

 

f = fMAX = 1/tCYC

 

 

 

 

 

 

 

 

 

(x18)

 

 

1115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(x36)

 

 

1140

 

 

 

 

 

 

 

 

 

 

ISB1

Automatic Power down

Max VDD,

 

(x8)

 

 

405

mA

 

Current

Both Ports Deselected,

 

 

 

 

 

 

 

 

(x9)

 

 

405

 

 

 

VIN VIH or VIN VIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(x18)

 

 

405

 

 

 

f = fMAX = 1/tCYC, Inputs Static

 

 

 

 

 

 

 

 

(x36)

 

 

405

 

 

 

 

 

 

 

 

 

 

AC Electrical Characteristics

Over the Operating Range [13]

Parameter

Description

Test Conditions

Min

Typ

Max

Unit

VIH

Input HIGH Voltage

 

VREF + 0.2

V

VIL

Input LOW Voltage

 

VREF – 0.2

V

Notes

17.Power up: Assumes a linear ramp from 0V to VDD(min) within 200 ms. During this time VIH < VDD and VDDQ < VDD.

18.Output are impedance controlled. IOH = (VDDQ/2)/(RQ/5) for values of 175 ohms <= RQ <= 350 ohms.

19.Output are impedance controlled. IOL = (VDDQ/2)/(RQ/5) for values of 175 ohms <= RQ <= 350 ohms.

20.VREF (min) = 0.68V or 0.46VDDQ, whichever is larger, VREF (max) = 0.95V or 0.54VDDQ, whichever is smaller.

Document Number: 001-12560 Rev. *C

Page 21 of 27

[+] Feedback

Page 21
Image 21
Cypress CY7C1515JV18 Maximum Ratings, DC Electrical Characteristics, AC Electrical Characteristics, Operating Range