AutoStore INHIBIT or Power Up RECALL
Parameter | Alt | Description |
|
| Unit | ||
Min |
| Max | |||||
|
|
|
|
|
| ||
t | [9] | tRESTORE | Power up RECALL Duration |
|
| 550 | μs |
HRECALL |
|
|
|
|
|
|
|
tSTORE |
| tHLHZ | STORE Cycle Duration |
|
| 10 | ms |
VSWITCH |
|
| Low Voltage Trigger Level | 4.0 |
| 4.5 | V |
VRESET |
|
| Low Voltage Reset Level |
|
| 3.6 | V |
Figure 10. AutoStore INHIBIT/Power Up RECALL
VCC
5V |
VSWITCH |
VRESET |
STORE INHIBIT
tHRECALL
DQ (DATA OUT)
BROWN OUT | BROWN OUT | BROWN OUT | |||||||
RECALL | STORE INHIBIT | STORE INHIBIT | STORE INHIBIT | ||||||
|
|
|
|
|
|
|
|
|
|
| NO RECALL | NO RECALL | RECALL WHEN | ||||||
| (VCC DID NOT GO | (VCC DID NOT GO | VCC RETURNS | ||||||
| BELOW VRESET) | BELOW VRESET) | ABOVE VSWITCH |
Notes
9. tHRECALL starts from the time VCC rises above VSWITCH.
Document Number: | Page 9 of 15 |
[+] Feedback