Setting the Temperature System

You can set the upper and lower temperature warning systems for your switch’s backplane and slot 1.

To configure the temperature warning systems:

1.In the System Information section of the Web Agent window, click Temperature. The Temperature System dialog box opens.

2.Enter the desired temperature warnings for the switch backplane and slot 1 sensors, and enter the desired temperature warning for the CPU sensor.

3.Click on APPLY to save your changes, or Defaults to restore the temperature defaults.

*Note: The supervisor modules shut down the switching modules if the temperature reaches the Shutdown temperature. The modules are restarted if the temperature goes below the Upper Warning Temperature. The default Shutdown temperature for the slot 1 sensor and backplane sensor is 50° C. You can set the warning temperature to a value lower than 50° C to ensure prompt notification of an over-temperature situation.

Displaying the Power System Statistics

To display the power system statistics:

1.In the System Information section of the Web Agent window, click Power System. The Power System dialog box opens.

2.Use Table26 to review your power system statistics:

Table 26. Power System Statistical Parameters

Parameter

Definition

 

 

Power Supply

Indicates the power supply is present.

 

 

Status

Identifies if the power supply is working properly.

 

 

Type

Describes the type of power supply detected.

 

 

2 - 46

Cajun P880 Routing Switch Installation Guide

Page 80
Image 80