Table 26. Power System Statistical Parameters

Parameter

Definition

 

 

Total System

Displays the total system power in Watts.

Power

 

 

 

Current

Displays the current power available.

Power

 

Available

 

 

 

*Note: The power system settings only display 1400W of available power with two or three power supplies installed. A maximum configured switch requires a maximum of two power supplies. A third power supply may be added for redundancy in the event one of the other power supplies fails. All three power supplies will load-share during redundant operation. The remaining power supplies will share the full system load, in the event that the third power supply fails.

Displaying Cooling System Statistics

To display the switch’s cooling system status:

1.In the System Information section of the Web Agent window, click Cooling System. The Cooling System dialog box opens.

2.Ensure that all the individual components are operational by checking the status column for each component.

3.If a component’s status is non-operational, power down the Caju P880 Switch and contact a service representative to diagnose the failing unit.

Configuring Redundant Hardware

The Cajun P880 switch provides a redundant controllers and elements to ensure that if a controller or an element fails, the switch will continue to route data properly. The redundant components are available as separate options.