2
CAUTION
Replacing an Element
CAUTION
Before replacing switch controllers or elements, you must turn off the switch.
5.Replace the failed primary controller by inserting it in the slot to the right of the redundant controller and to the left of element three.
6.Restart the switch and login.
7.In the System Information section of the Web Agent, click Switch Fabric. The Switch Fabric Status dialog box displays.
8.From the Configure Redundant Hardware
9.Click APPLY to enable the redundant controller.
The Switch Controller field displays # 1 Active to show that the redundant controller is now enabled.
10.In the Toggle Active Controller field, click Toggle to restore control to the primary controller.
The Switch Controller field displays # 0 Active to show that the primary controller is now enabled.
If an element fails, you are notified by a console message and an event log message. In the Web Agent, the Switch Elements field displays # Failed <number>, where <number> is the number that indicates the failed element.
To configure the redundant element:
1.In the System Information section of the Web Agent window, click Switch Fabric. The Switch Fabric Status dialog box displays.
2.From the Configure Redundant Hardware
3.Click Apply to disable the failed element.
4.Shut down the switch.
Before replacing switch controllers or elements, you must turn off the switch.
2 - 50 | Cajun P880 Routing Switch Installation Guide |