Installing/Removing Switch Controllers/Elements

The following sections explain how to install switch controllers and elements.

Installing Redundant Controllers/Elements

By default, the switch is configured without the redundant controller or element.

Before replacing switch controllers or elements, turn off the

Cajun P880 Switch.

CAUTION

To install the redundant modules and enable module redundancy:

1.Turn power off and unplug the Cajun P880 Switch.

2.Using a Phillips-head screwdriver, loosen the captive screws on the rear panel.

3.Carefully pull the rear panel away from the chassis.

4.Carefully remove the Switch Element or Switch Controller card from the shipping box.

5.In order to take appropriate antistatic precautions, plug your ESD strap/device into the jack (this takes a standard banana jack) on the chassis (Figure 12), and carefully remove the card from the antistatic wrap.

*Note: The ESD jack is only available when the rear panel has been removed.