Daewoo KOG-373R0S Trouble Shooting Guide, Malfunction of, Disconnect high voltage fuse

Models: KOG-376T1S KOG-391G0S KOG-391H0S KOG-393R0S KOG-396T1S KOG-371R0S KOG-391R0S KOG-375R0S KOG-374R0S KOG-373R0S KOG-371H0S

1 103
Download 103 pages 31.34 Kb
Page 46
Image 46
TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

Following the procedure below to check if the oven is defective or not.

1)Check earthing before trouble checking.

2)Be careful of the high voltage circuit.

3)Discharge the high voltage capacitor.

4)When checking the continuity of the switches, fuse or high voltage tranformer, disconnect one load wire from these parts and check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.

NOTE : When electric parts are checked, be sure the power cord is not inserted the wall outlet.

Check wire harness, wiring and connected of the terminals and power cord before check the parts listed below.

(TROUBLE 1) Oven does not operate at all : any inputs can not be accepted.

CONDITION

Fuse blows.

CHECK

 

 

 

RESULT

 

 

Check continuty of interlock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continuity

 

 

monitor switch with door closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(COM NC)

 

 

 

 

 

 

 

 

 

 

No Continuity

 

 

 

 

 

 

 

 

 

CAUSE

Malfunction of interlock monitor switch

REMEDY

Replace

NOTE 1

Check continuity of both

No Continuity

 

primary and secondary

Malfunction of

interlock switch with door

 

colosed

Continuity

interlock switch

 

 

Replace

NOTE 1

Check continuity of primary Malfunction of interlock switch contact with door

partially open until interlock monitor switch contact close (COM NC)

Check continuity of primary winding of low voltage transformer

Continuity

Disconnect high voltage fuseManual background 0Ω or infinite Manual backgroundManual background

Approx.

150~310

(normal)

Shorted contacts of primary interlock switch.

Defective low voltage transformer

Replace

NOTE 1

Replace

Disconnect high voltage fuse

 

 

Fuse again

 

 

Defective high

 

 

 

 

 

 

 

 

 

 

voltage

 

and operate the unit

 

 

blows

 

 

 

 

 

 

 

transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

45

Page 46
Image 46
Daewoo KOG-373R0S, KOG-371H0S, KOG-374R0S, KOG-375R0S Trouble Shooting Guide, Malfunction of, Disconnect high voltage fuse