PRINTED CIRCUIT BOARD <KOG-376T1S, KOG-396T1S>

1. CIRCUIT CHECK PROCEDURE

1.Low voltage transformer check

The low voltage transformer is located on the P.C.B. Measuring condition : Input voltage : 230V/Frequency : 50Hz

Terminal Voltage

LOAD

NO LOAD

8 - 9

AC 23V

AC 27.7V

 

 

 

6 - 7

AC 2.27V

AC 2.79V

 

 

 

NOTE

1.Refer to Circuit Diagram (point 4).

2.Secondary side voltage of the low voltage trasformer changes in proportion to fluctuation of power source voltage.

3.The allowable tolerance of the secondary voltage is within 5% of nominal voltage.

2.Voltage Check - Key check point

NO

CHECK POINT

REMARK

 

 

 

1

IC1 PIN 6, 10, 11

-5VDC

 

 

 

2

IC1 PIN 22

 

T : 20ms(50Hz)

3

IC1 PIN 8 OR 9

 

 

 

 

 

 

 

 

 

 

T : 250 ns(4MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

MEASURE POINT

WAVE FORM

 

REMEDY

 

REMARK

 

 

 

 

 

 

 

1

MP1

DC -5V±0.25V

 

 

Replace VL1, EC1

 

NO LOAD

 

 

 

 

 

 

 

2

MP2

DC -24V±2.0V

 

 

Replace EC3, D8-11

 

NO LOAD

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

Each measure point must be measured with GND points.

60

Page 61
Image 61
Daewoo KOG-371H0S, KOG-373R0S, KOG-374R0S Printed Circuit Board KOG-376T1S, KOG-396T1S, Wave Form Remedy Remark