Daewoo KOG-373R0S PRINTED CIRCUIT BOARD KOG-371G/H0S, KOG-391G/H0S, Circuit Check Procedure

Models: KOG-376T1S KOG-391G0S KOG-391H0S KOG-393R0S KOG-396T1S KOG-371R0S KOG-391R0S KOG-375R0S KOG-374R0S KOG-373R0S KOG-371H0S

1 103
Download 103 pages 31.34 Kb
Page 55
Image 55
PRINTED CIRCUIT BOARD <KOG-371G/H0S, KOG-391G/H0S>

PRINTED CIRCUIT BOARD <KOG-371G/H0S, KOG-391G/H0S>

1. CIRCUIT CHECK PROCEDURE

1.Low voltage transformer check

The low voltage transformer is located on the P.C.B. Measuring condition: Input voltage: 230V / Frequency: 50Hz

Terminal Voltage

LOAD

NO LOAD

 

 

 

4-7

AC 25.8 V

AC 28.4 V

 

 

 

NOTE

1.Refer to Ciruit Diagram (point 4).

2.Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.

3.The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.

2.Voltage Check - Key check point

NO

CHECK POINT

REMARK

 

 

 

1

IC1 PIN 2, 21, 30, 34

-5VDC

 

 

 

2

IC1 PIN 35

 

T : 20ms(50Hz)

3

IC1 PIN 31 OR 32

T : 250 ns(4MHz)

- Check method

NO

MEASURE POINT

WAVE FORM

REMEDY

REMARK

 

 

 

 

 

1

MP1

DC -5V±0.25V

Replace VL1, EC1

NO LOAD

 

 

 

 

 

2

MP2

DC -12V±2.0V

Replace EC2, D12,13,14

NO LOAD

 

 

 

 

 

NOTE

Each measure point must be measured with GND points.