1. CIRCUIT CHECK PROCEDURE

1. Low Voltage Transformer check

The low voltage transformer is located on the P.C.B.

Measuring condition: input voltage : 230V/Frequency : 50Hz

Terminal Voltage

LOAD

NO LOAD

 

 

 

4-7

AC 25.8 V

AC 28.4 V

 

 

 

NOTE :

1.Refer to Circuit Diagram (point 4).

2.Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.

3.The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.

2.Voltage check

• Key check point

NO

CHECK POINT

 

 

 

 

 

 

 

 

 

 

 

 

REMARK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

IC 1 PIN 2, 21, 30, 34

 

 

 

 

 

 

 

 

 

 

 

 

–5 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

IC 1 PIN 35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

T:20ms(50Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–5V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

IC 1 PIN 31 OR 32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–5V

 

 

 

 

 

T

 

 

 

 

T: 250 ns (4MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

MEASURE POINT

 

WAVE FORM

 

 

 

 

 

 

 

 

 

REMEDY

 

REMARK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

MP1

 

DC -5V±0.25V

 

 

 

 

 

 

 

 

Replace VL1, EC1

 

NO LOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

MP2

 

DC -12V±2.0V

 

 

 

 

 

 

Replace EC2, D6, D11, D12

 

NO LOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE :

Each measure point must be measured with GND points.