Daewoo KOG-376T1S Component Test Procedure, High voltage transformer, High voltage capacitor

Models: KOG-376T1S KOG-391G0S KOG-391H0S KOG-393R0S KOG-396T1S KOG-371R0S KOG-391R0S KOG-375R0S KOG-374R0S KOG-373R0S KOG-371H0S

1 103
Download 103 pages 31.34 Kb
Page 52
Image 52

3.COMPONENT TEST PROCEDURE

High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.

It is neither necessary nor advisable to attempt measurement of the high voltage.

Before touching any oven components or wiring, always unplug the oven from its power source and discharge the capacitor.

1.High voltage transformer

1)Remove connections from the transformer terminals and check continuity.

2)Normal readings should be as follows : Secondary winding ... Approx. 110 Ω ±10% Filament winding ... Approx. 0 Ω Primary winding ... Approx. 1 Ω

2.High voltage capacitor

1)Check continuity of capacitor with meter on the highest OHM scale.

2)A normal capacitor will show continuity for a short time, and then indicate 10MΩ once the capacitor charged.

3)A shorted capacitor will show continuous continuity.

4)An open capacitor will show constant 10MΩ .

5)Resistance between each terminal and chassis should be infinite.

3.High voltage diode

1)Isolate the diode from the circuit by disconnecting the leads.

2)With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals. Reverse the meter leads and again observe the resistance reading. Meter with 6V, 9V or higher voltage batteries

should be used to check the front-back resistance of the diode, otherwise an infinite resistance may be read in both directions. A normal diode's resistance will be infinite in one direction and several hundred k Ω in the other direction.

4.Magnetron

For complete magnetron diagnosis, refer to "Measurement of the Microwave Power Output." Continuity checks can only indicate and open filament or a shorted magnetron. To diagnose for an open filament or a shorted magnetron,

1)Isolate magnetron from the circuit by disconnecting the leads.

2)A continuity check across magnetron filament terminals should indicate 0.1 Ω or less.

3)A continuity check between each filament terminal and magnetron case should read open.

5.Fuse

If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and monitor switch before replacing the blown fuse. In case the fuse is blown by an improper switch operation, replace the defective switch and fuse at the same time. Replace just the fuse if the switches operate normally.