Daewoo KOG-391H0S, KOG-371H0S Measurement And Test, Measurement Of The Microwave Power Output

Models: KOG-376T1S KOG-391G0S KOG-391H0S KOG-393R0S KOG-396T1S KOG-371R0S KOG-391R0S KOG-375R0S KOG-374R0S KOG-373R0S KOG-371H0S

1 103
Download 103 pages 31.34 Kb
Page 50
Image 50
MEASUREMENT AND TEST

MEASUREMENT AND TEST

1. MEASUREMENT OF THE MICROWAVE POWER OUTPUT

Microwave output power can be checked by indirectly mmeasuring the temperature rise of a certain amount of water exposed to the microwave as directed below.

PROCEDURE

1.Microwave power output measurement is made with the microwave oven supplied at rated voltage and operated at its maximum microwave power setting with a load of 100 ± 5cc of potable water.

2.The water is contained in a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm and an outside diameter of approximately 190 mm.

3.The oven and the empty vessel are at ambient temperature prior to the start of the test. The initial temperature of the water is 10 ± 2°C (50 ± 3.6°F). If is measured immediately before the water is added to the vessel. After addition of the water to the vessel, the load is immediately placed on the center of the shelf, which is in the lowest normal position.

4.Microwave power is switched on.

5.Heating time should be exactly A seconds. (Refer to table as following)

Heating time is measured while the microwave generator is operating at full power. The filament heat- up time for magnetron is not included.

6. The initial and final temperature of water is selected so that the maximum difference between the ambient and final water temperature is 5K.

7.The microwave power output P in watts is calculated from the following formula:

P = 4187 X ΔT/t

ΔT is difference between initial and ending temperature.

t is the heating time.

The power measured be B (Refer to SPECIFICATIONS) W ± 10.0 %.

CAUTION

1.Water load should be measured exactly to 1 liters.

2.Input power voltage should be exactly specified voltage (Refer to SPECIFICATIONS).

3.Ambient temperature should be 20 ± 2°C (68 ± 3.6°F)

Heating time for power output:

A (second)

70

64

60

56

52

49

47

44

42

40

38

 

 

 

 

 

 

 

 

 

 

 

 

B (W)

600

650

700

750

800

850

900

950

1000

1050

1100

 

 

 

 

 

 

 

 

 

 

 

 

49

Page 50
Image 50
Daewoo KOG-391H0S, KOG-371H0S, KOG-373R0S, KOG-374R0S Measurement And Test, Measurement Of The Microwave Power Output