Regency E33-NG, E33-LP Operating Instructions, Final Check, First Fire, Lighting Procedure

Models: E33-NG E33-LP

1 32
Download 32 pages 55.69 Kb
Page 18
Image 18
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50

Ft.

16 GA.

32

Ft.

18 GA.

20

Ft.

20 GA.

12

Ft.

22 GA.

9

Ft.

 

 

 

 

 

 

FINAL CHECK

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

OPERATING

INSTRUCTIONS

2)

Turn gas control knob so indicator points

 

to "OFF" position and allow 5 minutes for

 

any gas in the combustion chamber to

 

escape.

3)

Turn gas control knob counterclockwise

 

so indicator points to the "PILOT" position.

 

Depress the gas control knob fully. Depress

 

the ignitor button several times until the

 

pilot lights. After approximately one minute,

 

release the gas control knob. The pilot fl ame

 

should continue to burn. If the pilot does not

 

remain lit, repeat operation allowing a longer

 

period before releasing gas control knob.

4)

When the pilot stays lit, turn the gas knob

 

further counterclockwise to the "ON" posi-

 

tion.

5)

Reinstall the glass door (refer to page 14).

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:

1)Clocking the appliance to ensure the cor- rect fi ring rate (rate noted on label) at 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.

FIRST FIRE

The fi rst fi re in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When

rst operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appli- anceislit,itmaycausecondensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed.

5)Verify that the venting and cap are unob- structed.

6)Ensure that the brick panels, if used, are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

LIGHTING

PROCEDURE

IMPORTANT

Prior to igniting or reigniting the

pilot, remove the glass door.

Only when the pilot holds, without pressure being applied to the control knob, should you reinstall the glass door. The unit must not be operated with the glass door removed.

IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

6)

Use the switch, thermostat or remote control

 

to turn on the unit.

7)

Rotate the fl ame height regulator to adjust

 

the fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

3)Turn off all electric power to appliance if service is to be performed.

18

E33 FPI Direct Vent Gas Insert

Page 18
Image 18
Regency E33-NG, E33-LP Operating Instructions, Final Check, First Fire, Lighting Procedure, Shutdown Procedure