Regency E33-NG Maintenance, Valve Assembly, Removal And Installation, Screws, Air Shutter Wire

Models: E33-NG E33-LP

1 32
Download 32 pages 55.69 Kb
Page 22
Image 22
Straighten adjustment wire.

MAINTENANCE

13)Pull Fan Assembly forward, to disengage the fan clip on the rear wall. Then lift the Fan Assembly up and pull through fi rebox opening.

7)Remove base brick set. (When removing base brick sides the two screws that hold the grate down must be removed fi rst).

Screws

8)Straighten the adjustment wire under the fi rebox base.

11)Disconnect the inlet gas line.

12)Unplug the black and red wires at the valve. Undo the 2 TP wires at the valve.

13)Remove the 17 screws on the valve tray.

14)Take out the valve tray from the unit.

Air Shutter Wire

14)Disconnect green wire from power cord.

Straighten adjustment wire.

9) Remove the Burner by removing the 2 screws (1 on burner bracket and one on valve tray). Tilt up the left burner and slide to the left away from the orifi ce.

15)

Scrape off the old gasket from the floor of the

 

fi rebox and from the valve access plate.

16)

Install new gasket and valve assembly
Replacing fan:

15)Reverse above steps.

Sealfanaccesspanelusinghightemperature silicone (sparingly).

VALVE ASSEMBLY

REMOVAL AND INSTALLATION

1)Turn the unit off and allow it to cool down to room temperature.

2)Unplug or disconnect power source.

3)Shut off the main gas supply.

4)Remove the louvers and glass door (refer to page 14).

5)Remove logs and grate (refer to page 10).

6)Remove optional brick set, if installed (refer to page 9).

Screws

10)Remove the rear log support by unscrewing the 2 screws.

Screws

(reverse steps 9-14).

NOTE: Failure to install a new gasket may severely affect the appliance perfor- mance.

17)Hook up gas line and check for gas leaks with soap and water solution or a gas leak detector. Do not use open flame for leak testing.

18)Set up the air shutter to 5/16" for NG and 7/16" for LP.

19)Fire up the unit temporarily.

20)Check the manifold pressure 3.8" W.C. for NG and 11" W.C. for LP.

21)Reverse steps 4-8.

22

E33 FPI Direct Vent Gas Insert

Page 22
Image 22
Regency E33-NG Maintenance, Valve Assembly, Removal And Installation, Screws, Air Shutter Wire, Straighten adjustment wire