10)Attach the faceplate panels to the insert body using the 4 remaining black screws. Refer to Diagram 5.

Securedoorbyfasteningwithtwoscrewslocated at bottom of glass frame (refer to Diagram 1).

To remove the fl ush door, reverse the above steps.

FLUSH LOUVERS

1)The top louver is held in place by friction fi t. Refer to Diagram 1

Diagram 5

11)Push the FPI logo plate into the two holes in the bottom left corner of the faceplate.

STANDARD

FLUSH DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (Diagram 1 and 2). Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Refer to Diagram 3.

Diagram 1

Screws

Diagram 1

2)Install the Spring Hinges on the left and right side of the bottom of the Firebox using 2 screws per hinge.

3)Place the Bottom Louver near the hinge. Flip hinge over the Bottom Louver and secure using 3 screws.

Hinge

Location

Bottom Louver

2)Lift the unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit.

Push in Corners

Bottom Trim STANDARD

Bracket

3)Completely secure faceplate to the unit by securing 4 screws to the Left and Right Side Trim.

Diagram 2

Diagram 3

FULL SCREEN FRONT

1)Hold the full screen faceplate up against the unit in order to make the following wire connections.

Pull the ON/OFF connector wires thru the box and connect them to the switch.

Connect the fan switch wires with the wire connectorsfromthefanspeedcontrol.Place clips over wires and tuck into side trim.

4)Install the Top Frame by hooking it onto the two screws at the top of the full screen door. It is held in place by magnets.