DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1.8.7 Improper Basket Lift Function (cont.)
Electronics failure. This category encompasses problems with the relays, microswitches, capacitors, resistors, interface board, wiring, and controls.
Troubleshooting the electronics of the modular basket lift is simply a process of verifying current flow through the components up to and including the motor. Using a multimeter set to the 250 VAC range, check the connections on both sides of the component for the presence of 120 VAC. The simplified wiring diagrams on the preceding pages identify the components and wiring connection points.
1.9Troubleshooting Guides
The following troubleshooting guides are intended to assist service technicians in quickly isolating the probable causes of equipment malfunctions by following a logical,
PROBLEM |
| PROBABLE CAUSES |
| CORRECTIVE ACTION | |
|
|
| |||
Burner will not ignite. | A. ON/OFF switch is off. | A. Turn ON/OFF switch on. | |||
Light in ON/OFF switch |
|
|
|
| |
is not illuminated. |
|
|
|
| |
|
|
|
| ||
ON/OFF switch is on, | A. | No voltage at switch. | A. Ensure line voltage is present at the | ||
but the switch light is not |
|
|
| switch. | |
illuminated. |
|
|
|
| |
|
|
| |||
| A. Drain microswitch circuit (filter- | A. Ensure drain valve is fully closed and | |||
|
| equipped units) is open. |
| microswitch is functioning. Replace | |
|
|
|
| microswitch if defective. | |
|
|
|
| ||
| B. Voltage is present at ON/OFF switch, | B. | ON/OFF switch is defective. Replace | ||
ON/OFF switch is on and |
| but continuity of the switch in ON |
| switch with a known working switch. | |
the switch light is |
| position is not "0.” |
|
| |
illuminated, but there is |
|
|
|
| |
C. Continuity of thermostat is not "0" | C. | Thermostat(s) is/are defective. | |||
no output to gas valve. | |||||
|
| (oil temperature is at least 15°F below |
| Replace defective thermostat with a | |
|
| electronic/ operating thermostat |
| known working thermostat. | |
|
| setting). |
|
| |
|
|
|
|
| |
| D. | Gas valve is suspect. | D. | Go to "No burner flame" section. | |
|
|
|
|
| |
|
|
|
|
|