Frymaster FPD 1.9Troubleshooting Guides, Improper Basket Lift Function cont, Service Procedures

Models: CFD D SCFD FPD

1 100
Download 100 pages 42.21 Kb
Page 44
Image 44
1.8.7 Improper Basket Lift Function (cont.)

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.8.7 Improper Basket Lift Function (cont.)

Electronics failure. This category encompasses problems with the relays, microswitches, capacitors, resistors, interface board, wiring, and controls.

Troubleshooting the electronics of the modular basket lift is simply a process of verifying current flow through the components up to and including the motor. Using a multimeter set to the 250 VAC range, check the connections on both sides of the component for the presence of 120 VAC. The simplified wiring diagrams on the preceding pages identify the components and wiring connection points.

1.9Troubleshooting Guides

The following troubleshooting guides are intended to assist service technicians in quickly isolating the probable causes of equipment malfunctions by following a logical, step-by-step process.

PROBLEM

 

PROBABLE CAUSES

 

CORRECTIVE ACTION

 

 

 

Burner will not ignite.

A. ON/OFF switch is off.

A. Turn ON/OFF switch on.

Light in ON/OFF switch

 

 

 

 

is not illuminated.

 

 

 

 

 

 

 

 

ON/OFF switch is on,

A.

No voltage at switch.

A. Ensure line voltage is present at the

but the switch light is not

 

 

 

switch.

illuminated.

 

 

 

 

 

 

 

 

A. Drain microswitch circuit (filter-

A. Ensure drain valve is fully closed and

 

 

equipped units) is open.

 

microswitch is functioning. Replace

 

 

 

 

microswitch if defective.

 

 

 

 

 

B. Voltage is present at ON/OFF switch,

B.

ON/OFF switch is defective. Replace

ON/OFF switch is on and

 

but continuity of the switch in ON

 

switch with a known working switch.

the switch light is

 

position is not "0.”

 

 

illuminated, but there is

 

 

 

 

C. Continuity of thermostat is not "0"

C.

Thermostat(s) is/are defective.

no output to gas valve.

 

 

(oil temperature is at least 15°F below

 

Replace defective thermostat with a

 

 

electronic/ operating thermostat

 

known working thermostat.

 

 

setting).

 

 

 

 

 

 

 

 

D.

Gas valve is suspect.

D.

Go to "No burner flame" section.

 

 

 

 

 

 

 

 

 

 

1-39

Page 44
Image 44
Frymaster FPD, SCFD manual 1.9Troubleshooting Guides, Improper Basket Lift Function cont, Decathlon Series Gas Fryers