1.7.8 Replacing the Frypot (cont.)

10.Remove screws securing flue-cap braces to frypot (a nut-driver with an extension or long screwdriver is required). Use care not to drop the screws into the flues. If this happens, the screws can be retrieved when the flue is removed (Step 16). Use a screwdriver or similar tool to free flue cap from frypots. Remove flue cap by lifting up and off of fryer.

Removing flue cap.

11.Remove gas manifold pipe for access to gas manifold shield by disconnecting at the unions. Ensure gas supply is shut off and supply line is disconnected prior to removing. Set gas manifold aside. Remove screws securing gas manifold shield. Remove shield to access oil-return plumbing components connected to the frypots.

NOTE: For units without built-in filtration skip the steps pertaining to removal and replacement of oil-return plumbing.

Removing gas manifold shield.

12.Remove cotter-pin from oil-return actuator rod. Observe washer placement prior to removing rod from the valve actuator (arrows). Disconnect actuator rod and remove washers. Set washers aside for later re-assembly.

Disconnecting oil-return linkage from valve.