Frymaster FPD, SCFD manual Decathlon Series Gas Fryers, Service Procedures

Models: CFD D SCFD FPD

1 100
Download 100 pages 42.21 Kb
Page 18
Image 18
Manual background

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.2 Replacing the Backup Thermostat (if applicable)

1.Disconnect the fryer from the electrical supply.

2.Drain cooking oil from frypot.

3.Remove thermostat knob.

4.Disconnect the wiring plug(s) from the component shield/control box.

5.Disconnect leads from terminal block.

6.Remove screws securing the thermostat bracket to fryer.

7.Follow Steps 5-7 in Section 1.7.4, Replacing the High-limit Thermostat, to remove thermostat from frypot.

8.Remove the defective thermostat from the thermostat bracket and replace with a known good thermostat. Use care not to damage the probe bulb and lead on the new thermostat.

9.Reverse the above steps to install the replacement.

Manual background CAUTION

The backup operating thermostat must be calibrated after installation is complete.

Refer to Section 1.6.2 for calibration instructions.

1-13