DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

Interface Boards (cont.)

P/N 806-4549 INTERFACE BOARD (previous style)

LED DIAGNOSTIC LIGHTS

12V

Indicates 12 VAC from transformer

24V

Indicates 24 VAC from transformer

GV

Indicates 24 VAC to gas valve

PWR

Indicates 24 VAC to PWR via K1 (L) or K2 (R or F)

AIR

Not Applicable to Decathlon Series Gas Fryers

The board contains two heat relays (K2 and K3), and two basket lift relays (K1 and K4). NOTE: On factory-original units not equipped with basket lifts and on service interface boards, the board will have no basket lift relays installed.

INTERFACE BOARD

J2

12VAC TO CPTR GROUND

12 VAC RETURN

COMPUTER

COMPUTER

COMPUTER

COMPUTER

NOT USED

1

2

3

4

5

6

7

8

J3 PIN 3

GROUND

J3 PIN 1

RT HT RELAY (K3)

12 VDC TO RELAYS

LT HT RELAY (K2)

K4

NOT USED

*Twin Vat configurations

**Single Vat configurations

*

 

COMPUTER

9

 

 

K1

 

 

 

 

 

 

 

 

 

RT ALARM OUT**

 

 

 

ALR (RIGHT)

 

 

 

 

 

 

 

 

10

 

COMPUTER

 

 

 

SOUND DEVICE

 

 

 

 

 

 

 

 

11

 

LT ALARM OUT*

 

 

 

AD (LEFT)

 

 

 

 

 

 

 

 

 

 

COMPUTER

 

12

 

 

J3 PIN 4

 

 

 

 

 

 

COMPUTER

 

13

 

 

J1 PIN 2 & J3 PIN 2

 

 

 

 

 

 

COMPUTER

14

 

 

J1 PIN 4

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

 

 

 

 

 

 

 

 

 

J3

 

 

 

 

 

 

 

NOT USED

 

 

 

 

 

 

NOT USED

 

 

 

J2 PIN 3

 

 

 

 

12 VAC XFMR PIN 12

 

 

TEMP PROBE

 

 

1

 

 

 

J2 PIN 14

 

 

 

J2 PIN 14

 

 

1

 

 

TEMP PROBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

2

 

 

 

 

NOT USED

 

 

 

 

 

NOT USED

 

 

 

J2 PIN 1

 

 

 

 

12 VAC XFMR PIN 11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

3

 

 

 

 

TEMP PROBE

 

 

 

 

 

J2 PIN 15

 

 

 

J2 PIN 13

 

 

 

 

TEMP PROBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOT USED

 

 

 

 

 

NOT USED

 

 

 

NOT USED

 

 

 

 

NOT USED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

5

 

 

 

 

NOT USED

 

 

 

 

 

NOT USED

 

 

 

NOT USED

 

 

 

 

NOT USED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAIN GAS VALVE

 

6

 

 

 

V2D

 

 

 

V1S OR V1D

 

 

6

MAIN GAS VALVE 24VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

via HLS

 

 

7

 

 

 

PWR via K1

 

 

 

PWR via K2

 

 

 

7

 

 

via HLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC IN

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC IN

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

BASKET LIFT (DN)

 

 

K1

 

 

 

K4

 

 

 

 

BASKET LIFT (DN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

9

 

 

 

NOT USED

 

 

 

 

 

NOT USED

 

AC Hot to 120VAC GV

 

MAIN GAS VALVE 120VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

via HLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC COMMON

 

 

 

 

 

AC COMMON

 

 

 

AC COMMON

 

 

 

 

 

AC COMMON

 

 

BASKET LIFT (UP)

 

 

11

 

 

 

K1

 

 

 

K4

 

 

11

 

BASKET LIFT (UP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

MOD 25V GROUND

 

 

 

 

GROUND

 

 

 

GROUND

 

 

 

 

MOD 25V GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

GND

 

 

 

MOD V2D

 

 

 

 

J1 PIN 7

 

 

 

J3 PIN 7

 

 

 

MOD V1D*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V2D

 

 

 

 

 

V1D

 

 

 

 

MOD 25V TERM

 

 

 

J1 PIN 8 via K1

 

 

 

J3 PIN 8 via K2

 

 

 

MOD 25V TERM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

DRAIN SWITCH (OPT)

 

 

J2 PIN 12

 

 

 

J2 PIN 10

 

 

DRAIN SWITCH (OPT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AD

 

 

 

 

 

 

ALR

 

 

 

 

NOT USED

 

 

 

NOT USED

 

 

 

J3 PIN 7

 

 

 

MOD V1S**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOT USED

 

 

AS

 

 

NOT USED

 

 

 

 

 

 

 

V1S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V2S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEFT TWIN VAT

 

 

SINGLE OR RIGHT TWIN-VAT

CURRENT FLOW THROUGH INTERFACE

BOARD 806-4549 (previous style)

1-6

Page 11
Image 11
Frymaster FPD, SCFD manual Current Flow Through Interface