Frymaster FPD, SCFD manual Accessing Fryers for Servicing, SERVICE PROCEDURES Thermostats, Danger

Models: CFD D SCFD FPD

1 100
Download 100 pages 42.21 Kb
Page 12
Image 12
CHAPTER 1: SERVICE PROCEDURES

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

Thermostats

Different types of thermostats are used in Decathlon Series gas fryers, depending on fryer configuration.

Fryers equipped with an optional backup operating-thermostatand/or Thermatron use a dial to adjust temperature. In this configuration, the probe resistance varies directly with the temperature. As the temperature rises, resistance decreases at a rate of approximately 2 ohms for every 1°F (approximately 3.7 ohms for every 1°C).

Fryers equipped with computer controls have a temperature probe. In this configuration, the probe resistance varies directly with the temperature. As the temperature rises, resistance increases at a rate of approximately 2 ohms for every 1°F (approximately 3.7 ohms for every 1°C). Circuitry in the computer monitors the probe resistance and controls burner firing when the resistance exceeds or falls below programmed temperatures (setpoints). The temperatures are programmed by means of a keypad on the face of the computer.

All Decathlon Series gas fryers are equipped with a high-limit thermostat. In the event that the fryer fails to control the oil temperature, the high-limit thermostat prevents the fryer from overheating to flash point. The high-limit thermostat acts as a normally closed power switch that opens when exposed to temperatures above 410°F/210°C (CE) to 450°F/232°C (non-CE). CE and non-CE high- limits are not interchangeable.

1.2 Accessing Fryers for Servicing

1.2 Accessing Fryers for Servicing DANGER

Moving a fryer filled with cooking oil may cause spilling or splattering of the hot liquid. Follow the draining instructions included with the fryer before attempting to relocate a fryer for servicing.

1.Shut off the gas supply to the unit. Unplug the power cords. Remove any attached restraining devices.

2.Disconnect the unit from the gas supply.

3.Relocate the fryer for service accessibility.

4.After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords.

 DANGER DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.

1-7

Page 12
Image 12
Frymaster FPD, SCFD Accessing Fryers for Servicing, SERVICE PROCEDURES Thermostats, Danger, Decathlon Series Gas Fryers