1.7.8Replacing the Frypot (cont.)

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.8Replacing the Frypot (cont.)

27.Remove the temperature probe from frypot. (See Section 1.7.3, Replacing the Temperature Probe: Computer –equipped Fryers, for specific instructions.)

28.Remove the high-limit and backup thermostats. Follow Steps 5-7, Section 1.7.4, Replacing the High-limit Thermostat, and Section 1.7.2, Replacing Backup Thermostat, (where applicable) from frypot.

29.If the fryer is equipped with drain-valve microswitches, mark the wires and microswitch terminals, then disconnect wires from the switch. Secure the wires to prevent damage when frypot is removed.

Left: Microswitch wires marked for removal (ensure microswitch terminals are marked the same as the wires removed). Right: Microswitch mounted to drain valve.

30.Remove bolts from brackets securing burner manifold to frypot. Leave the manifold in place.

Removing bolts (arrows) from burner manifold support brackets (both sides). Leave the burner manifold in place after removing bolts.