1.9Troubleshooting Guides (cont.)

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.9Troubleshooting Guides (cont.)

 

A.

Pilot does not stay lit (fryer is on and

A.

Check high-limit switch.

Switch

 

 

thermopile output is approximately

 

continuity should be "0."

If not, high-

 

 

400 millivolts and/or thermocouple is

 

limit switch is defective. Replace

 

 

approximately 25 millivolts.

 

high-limit switch.

 

 

 

 

 

 

 

B.

Pilot does not stay lit (fryer is on and

B.

Inspect thermocouple (units without

 

 

thermopile output is not

 

interface board) or thermopile (units

 

 

approximately 400 millivolts or

 

with interface board) and replace if

 

 

thermocouple output is not 25

 

defective.

 

 

 

millivolts.

 

 

 

 

 

 

 

 

 

C.

Pilot stays lit, and the high-limit and

C.

Inspect gas valve and replace if

 

 

thermopile/thermocouple are known

 

defective.

 

 

 

working, but burners fail to light.

 

 

 

 

 

 

 

 

No burner flame.

D.

Gas valve is known to be good, but

D.

Inspect electronic/operating

 

there is not 24 VAC (120VAC on

 

thermostat sensor (while still in

 

 

 

 

 

systems so equipped) at the gas valve

 

frypot) for damage. Replace if bent,

 

 

terminals.

 

dented, or cracked. Inspect leads for

 

 

 

 

fraying, burning, breaks, and/or kinks.

 

 

 

 

If found, remove and replace

 

 

 

 

thermostat(s). Remove leads from

 

 

 

 

terminal block, allow oil to cool 15°F

 

 

 

 

(8°C) below thermostat setting, and

 

 

 

 

check continuity. If continuity is not

 

 

 

 

"0,” then thermostat has failed.

 

 

 

 

Replace thermostat(s).

 

 

 

 

 

 

 

E.

Continuity from terminal block to gas

E.

Inspect wiring for breaks or shorts and

 

 

valve electronic/operating thermostat

 

repair if necessary.

 

 

 

wire is not "0."

 

 

 

 

 

 

 

 

 

A.

Incoming gas supply pressures are not

A.

Inspect gas supply to fryer. Repair

 

 

within range [Natural- 6-14" W.C.

 

and/or replace faulty components

 

 

(1.49-3.49 kPa); Propane- 11-14"

 

(defective supply shut-off valves,

Fluctuating or erratic

 

W.C. (2.74-3.49 kPa)]

 

incorrect piping size, etc.)

 

 

 

 

 

 

B.

Air in gas supply lines (new

B.

Allow unit to cycle on and off for

lighting of burner flame.

 

 

installation).

 

approximately 30 minutes to force air

 

 

 

 

from gas manifold and lines.

 

 

 

 

 

Electronic/operating

A.

Electronic/operating thermostat is out

A.

Calibrate electronic/operating

thermostat will not adjust

 

of calibration.

 

thermostat. Replace if calibration is

to correct temperature.

 

 

 

not possible.

 

 

 

 

 

 

 

1-40

Page 45
Image 45