Danby APAC9036 Miseengarde, C A U T I O N During, Air Conditioner Operating Instructions cont’d

Models: APAC9036

1 24
Download 24 pages 27.22 Kb
Page 12
Image 12
Air Conditioner Operating Instructions (cont’d)

Air Conditioner Operating Instructions (cont’d)

4)Press the FAN key Fig F (1) to select the desired fan speed setting (Auto-Low-Med-High). Your selection will appear in the display window (each depression of the fan key will advance

to a different setting).

5)Press the SWING key Fig F (2) to activate the automatic air swing (oscillating) feature and the swing symbol will appear in the display window. Fig G. To deactivate the air swing feature, press the SWING key again.

6)The horizontal louvers open and close automatically when the unit is switched on and off. To adjust “air flow” direction, (up / down only) adjust the center louver only up or down Fig 16.

The blue indicator light will come on indicating the air-conditioning mode is operational (there may be a slight delay of 10-30 seconds before the cycle begins, this is normal).

Cooling stops automatically when the set temperature is achieved. Cooling resumes when the room temperature rises above the set temperature level. The temperature has no effect on the fan operation. Therefore, the fan will operate continuously (after the compressor has cycled off) to maintain optimal temperature control.

C A U T I O N During C A U T I O N During

During air conditioning and dehumidifying modes, if the compressor cycle is interupted (unplugged, power failure,etc.) and reinstated immediately thereafter, (within 3-5 minutes) a “compressor protection circuit” is automatically self-activated. The compressor cannot operate during a “compressor protecton” condition. (this is normal) It may take 3-5 minutes before the “protection circuit” self-deactivates.

DO NOT ATTEMPT TO START THE UNIT (COMPRESSOR) DURING THIS PERIOD. Upon reinstating power to the unit all previous settings (i.e. time, mode, fan speed, auto timed programs) are lost and will have to be re-entered.

12

Fig F

Fig G

Fig. 16

ATTENTION

When the unit beeps and the (red) “water full” indicator light illuminates and flashes continuously, please (re)install the external water tank.

 

 

 

Vidage Directe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sortie

 

Serrure pour le

 

D’eau

 

 

(réservoir

 

réservoir d'eau

 

 

 

externe)

 

externe

 

 

 

 

 

 

 

 

 

 

 

 

Support pour

 

 

 

 

 

 

 

accrocher le

 

 

 

 

 

réservoir d’eau

 

 

 

 

 

externe

 

 

 

 

 

 

 

 

 

 

Fig.38Drain inférieur

Manual background MISEENGARDE Manual background

En modes de climatisation et de déshumidification, si le cycle du compresseur est interrompu (par le débranchement de l’unité ou par une panne de courant, etc.) et immédiatement rétabli par la suite, (en dedans de 3 à 5 minutes) un circuit de protection du compresseur est automatiquement activé. Le compresseur ne fonctionnera pas en mode de protection. Ceci est normal et un délai de 3 à 5 minutes pourrait se produire avant que le circuit de protection du compresseur ne soit automatiquement désactivé.

NE PAS TENTER DE FAIRE DÉMARRER LE COMPRESSEUR DURANT CETTE PÉRIODE.

Avec la remise en service de l’unité (en tournant le commutateur I/O), toutes les informations de programme (c. à-d., heure, mode, vitesse du ventilateur, programmes temporisés) devront être programmées de nouveau.

IMPORTANT

Si vous prévoyez ne pas utiliser l’appareil sur une longe période, placez un plateau d'égouttement sous le drain inférieur et enlevez les bouchons (pas en même temps) pour libérer manuellement l'eau dans le sector de la réservor interne.

Fig.38

33F

10

Page 12
Image 12
Danby APAC9036 owner manual Miseengarde, C A U T I O N During, Air Conditioner Operating Instructions cont’d