ELECTRICAL REQUIREMENTS

(120V~/ 60HZ WITH THE 3 PRONG GROUNDING PLUG)

WARNING

GROUNDING INSTRUCTIONS

To reduce the risk of electrical shock or personal injury, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, and such local regulations as might apply. IT’S THE CONSUMERS RESPONSIBILITY TO HAVE THE WIRING FUSES AND CIRCUIT BREAKERS CHECKED BY A QUALIFIED ELECTRICIAN TO MAKE SURE YOUR HOME HAS ADEQUATE ELECTRICAL POWER TO OPERATE THE WASHER.

DO NOT OVERLOAD THE WASHERDO NOT USE AN ADAPTERDO NOT USE AN EXTENSION CORD

The washer must be grounded in the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electrical shock. The washer is equipped with a cord having an equipment grounding conductor and a 3 prong grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided with the washer, if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

If a positive ground cannot be established through the power cord and if local code permits its use, connect an external ground wire (18 gauge mini- mum, available at your local hardware store). Connect one end of the wire under any screw (located at rear of washer) and other end to a known effective electrical ground.

STANDARD 120 VOLT, 60 HERTZ, 3-WIREEFFECTIVELY GROUNDED CIRCUITNote:

Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than illustrated, a qualified electrician should correct the problem.

4