Standard 2 of 5

Standard 2 of 5 — continued

Standard 2 of 5 Length 1, Length 2 Programming Instructions

1.Scan the START bar code.

2.Scan either the Set Length 1 or Set Length 2 bar code.

3.Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in decimal notation.

For Standard 2 of 5 bar codes, all check and data characters are included in the length calcu- lations.

NOTE

4. Scan the END bar code.

START / END

PROGRAMMING BARCODES

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 008

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 050

Product Reference Guide

5-61

Page 135
Image 135
Datalogic Scanning 1000I manual Standard 2 of 5 Length 1, Length 2 Programming Instructions