Label Gone Timeout
Product Reference Guide
2-3
Label Gone Timeout
This feature sets the time after the last label segment is seen before the scanner prepares for a
new label.
Productivity Index Reporting (PIR)
When PIR is enabled, label quality data is appended to decoded data before being presented to
the POS. The PIR feature allows the scanner to provide information to an external computer,
indicating how easy the label was to read.
START / END
PROGRAMMING BARCODES
Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To
configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim-
eout,” followed by the three digits (zero padded) from the Alphanumeric table in AppendixC, Alpha-Numeric Pad representing the
desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 320 milliseconds (032)
Set Label Gone Timeout
NOTE
This value-added feature is a factory-programmed
option. Contact your dealer for information about
upgrading your system to include this advanced
capability.
START / END
PROGRAMMING BARCODES
Disable
DEFAULT
Enable