Software Control

XON/XOFF — this is software handshaking that allows the host to control data transmission. If the host sends an XOFF command to the scanner, the scanner will not send the bar code data until it receives an XON command from the host. If the host sends the XOFF command during data transmission, the host will receive additional characters for no more than 2msec1.

NOTE

Hardware/software controls are mutually exclusive. Enable only one of these features at a time, as enabling multiple controls can produce unpredictable results.

SET ----------------------------------------------

SOFTWRE CONTROL HARDWARE CONTROL

DISABLE HARDWARE CONTROL -----

ENABLE CTS/RTS FLOW CONTROL --

ENABLE CTS SCAN CONTROL ----

ENABLE XON/ XOFF ----------------

DISABLE XON/XOFF ----------------

END ----------------------------------------------

1 Varies slightly depending upon baud rate selected.