EURO 25 -1

36

INSTALLATION INSTRUCTIONS

INSTALLING THE EURO 25-1 GAS FIREPLACE INSERT HEATING APPLIANCE

INTO VENTED ZERO-CLEARANCE GAS FIREPLACE:

ARCHGARD T-100 SERIES

CAUTION: Installation must be conducted by a qualified gas appliance installer. Gas and electrical power must be disconnected from the host gas fireplace before installation can begin.

1.Remove the louvers and screens or glass door.

2.Remove the burner/sandpan assembly, valve and pilot assembly from the firebox bottom plate. Flip the plate over and leave the plate in place to support the gas insert.

3.Remove the facing cross members with an abrasive cutting disc or plasma cutter.

4.Remove the front top baffle with an abrasive cutting disc or plasma cutter.

5.Remove the flue deflector with a pair of sheet metal snips.

6.Replace the top louver.

7.The preparation of the host gas fireplace is complete. See Appendix A of the Euro-25-1 manual for further instructions. All installation requirements in the manual must also be carefully observed and followed.

8.Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.

REMOVE CUT

ITEM 3.

ITEM 4.

CUT

ITEM 5.

Page 36
Image 36
Delkin Devices EI - 25-1 manual Archgard T-100 Series