EURO 25 -1

37

INSTALLATION INSTRUCTIONS

INSTALLING THE EURO 25-1 GAS FIREPLACE INSERT HEATING APPLIANCE

INTO VENTED ZERO-CLEARANCE GAS FIREPLACE:

FMI MODEL 850 SERIES

CAUTION: Installation must be conducted by a qualified gas appliance installer. Gas and electrical power must be disconnected from the host gas fireplace before installation can begin.

1.Remove the screens or glass door.

2.Remove the burner assembly. (two 5/16” Hex screws at the back)

3.Remove the brick panels.

4.Remove the front top deflector. (four 5/16” Hex screws at the top)

5.Remove the valve tray. (two Philips screws on the sides)

6.Remove the bottom glass door clips. (two Philips screws)

7.The preparation of the host gas fireplace is complete. See Appendix A of the Euro-25-1 manual for further instructions. All installation requirements in the manual must also be carefully observed and followed.

8.Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.

*Optional custom surround is available for the 850 Series, Part # FMBP-25. With this part, minimal finishing work is required. It will fill in the opening around the insert. Please contact Archgard Industries for the availability of this part.

Page 37
Image 37
Delkin Devices EI - 25-1 manual FMI Model 850 Series