INSTALLATION INSTRUCTIONS

EURO 25 -1

9

INSTALLATION INSTRUCTIONS

CLEARANCES TO COMBUSTIBLES

SIDE VIEW

Combustible mantle allowed in shaded area. Mantle extension may be increased 1” (25 mm) for each additional 1” (25 mm) increase in clearance height.

Minimum Height From

Bottom of Appliance:

36” (915 mm)

Minimum Height From Top of Surround:

13” (330 mm)

6” (152 mm)

Non-combustible hearth is not required.*

*Observe building codes; the codes may require a non-combustible hearth.

TOP VIEW

Leveling leg

3” (76 mm)

 

3” (76 mm)

 

 

 

Clearances to Surround

Sidewalls or Mantle Supports

CAUTION: This appliance is designed for use in any masonry, factory-built wood burning and specific zero-clearance vented gas fireplaces (Due to constant additions, contact Archgard Industries for an updated list of suitable gas fireplaces). This appliance cannot be enclosed with combustible material and used as a built-in gas fireplace.