Dell 400 owner manual RAID Level 1 Configuration, Segment Hard drive

Models: 400

1 150
Download 150 pages 30.55 Kb
Page 29
Image 29

serial ATA RAID configured for RAID level 0

segment 1

segment 3

segment 5

hard drive 1

segment 2

segment 4

segment 6

hard drive 2

Another advantage of a RAID level 0 configuration is that it utilizes the full capacities of the drives. For example, if you have two 120-GB drives installed, you have 240 GB on which to store data.

NOTICE: Because RAID level 0 configurations provide no data redundancy, if one drive fails, then the data on the other drive is also inaccessible. Therefore, ensure that you perform regular backups when you use a RAID level 0 configuration.

RAID Level 1 Configuration

RAID level 1 uses a data-redundancy storage technique known as "mirroring." When data is written to the primary drive, it is then duplicated, or mirrored, on the other drive. A RAID level 1 configuration sacrifices high data-access rates for its data redundancy advantages.

Setting Up and Using Your Computer

29

Page 29
Image 29
Dell 400 owner manual RAID Level 1 Configuration, Segment Hard drive