Item

Name

Icon

Description

 

 

 

 

6

AC power status

 

• Off: AC power is off, or the power is on but the module is

 

indicator (2)

 

not in a controller, or it may indicate a hardware fault

 

 

 

• Steady green: AC power is on

 

 

 

• Blinking green: AC power is on and the PSU is in standby

 

 

 

mode

7

DC power fault

 

• Off: Normal operation

 

indicator (2)

 

• Steady amber: A PSU has been removed, or there is a DC

 

 

 

or other hardware fault, or there is a problem

 

 

 

communicating with the PSU

 

 

 

• Blinking amber: PSU is in programming mode

8

Power socket (2)

Accepts a standard computer power cord.

9

Power switch (2)

Controls power for the storage system. There is one switch for

 

 

 

each power supply/cooling fan module.

SCv2000/SCv2020 Storage Controller Features and Indicators

The SCv2000/SCv2020 includes up to two storage controllers in two interface slots. The storage controllers support Fibre Channel, iSCSI, or SAS front-end ports.

SCv2000/SCv2020 Storage Controller with Fibre Channel Front-End Ports

Features and indictors on a storage controller with Fibre Channel front-end ports.

Figure 3. Storage Controller with Four 8 Gb Fibre Channel Front-End Ports

Figure 4. Storage Controller with Two 16 Gb Fibre Channel Front-End Ports

Item

Control/Feature

Icon Description

 

 

 

1

Battery status indicator

• Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat

Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging

10

About the SCv2000/SCv2020 Storage System

Page 10
Image 10