Figure 13. Rear View of the Enclosure Showing the Failed Cooling Fan

Replacing a Power Supply/Cooling Fan Module

Use this procedure to replace a failed power supply/cooling fan module.

Prerequisites

1.Use SupportAssist to send diagnostic data to Dell Technical Support Services.

About this task

You can replace power supply/cooling fan modules one at a time without shutting down the storage system.

Steps

1.Press the power switch on the power supply/cooling fan module to turn it off.

2.Remove the hook-and-loop strap that secures the power cable and disconnect the power cable from the power supply/cooling fan module.

3.Push the release tab on the power supply/cooling fan module and slide it out of the chassis using the handle.

CAUTION: The power supply/cooling fan modules are heavy. To avoid injury, use both hands while removing the module.

Replacing SCv2000/SCv2020 Components

23

Page 23
Image 23
Dell E09J, E10J Replacing a Power Supply/Cooling Fan Module, Rear View of the Enclosure Showing the Failed Cooling Fan