SCv2080 Storage Controller with SAS Front-End Ports

Features and indictors on a storage controller with SAS front-end ports.

Figure 7. SCv2080 Storage Controller with Four 12 Gb SAS Front-End Ports

Item

Control/Feature

Icon Description

 

 

 

1

Battery status indicator

• Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat

Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging

Steady green: Battery is ready

2

Battery fault indicator

• Off: No faults

Blinking amber: Correctable fault detected

Steady amber: Uncorrectable fault detected; replace battery

3

MGMT port

10 Mbps, 100 Mbps, or 1 Gbps Ethernet port used for storage

 

 

 

system management and access to the BMC

 

 

 

NOTE: To use the MGMT port as an iSCSI port for

 

 

 

replication to another Storage Center, a Flex Port license

 

 

 

and replication license are required. To use the MGMT port

 

 

 

as a front-end connection to host servers, a Flex Port

 

 

 

license is required.

4

REPL port

10 Mbps, 100 Mbps, or 1 Gbps Ethernet/iSCSI port used for

 

 

 

replication to another Storage Center

 

 

 

NOTE: To use the RELP port as a front-end connection to

 

 

 

host servers, a Flex Port license is required.

5

SAS activity indicators

• Off: Port is off

 

 

 

• Steady green: Port is on, but without activity

 

 

 

• Blinking green: Port is on and there is activity

6

Storage controller

 

On: Storage controller completed POST

 

module status

 

 

7Recessed power off button

8Storage controller module fault

Powers down the storage controller if held for more than five seconds

Off: No faults

Steady amber: Firmware has detected an error

Blinking amber:Storage controller is performing POST

About the SCv2080 Storage System