Dell E11J001 owner manual Item

Models: E11J001

1 45
Download 45 pages 47.63 Kb
Page 9
Image 9
Manual background

Item

Name

Panel

Description

 

 

 

 

3

Drawer-specific left

 

Activity Bar Graph: Six variable-intensity LEDs

 

and right side

 

dynamically displaying access of the drives in

 

storage system

 

that specific drawer.

 

activity indicators

 

 

4

Status indicator for

Unit ID Display: A numerical display whose

 

storage system

 

primary function is to display the unit

 

 

 

identification number.

 

 

• Input Switch: Not currently used (though it

 

 

 

can be used to set the Unit ID Display, the ID

 

 

 

will be automatically reset by the Storage

 

 

 

Center Operating System)

 

 

Power On/Standby:

– Off — The storage system does not have power

– Green — The storage system is on (operational)

– Amber — The storage system is in standby (not operational)

• Module Fault: Amber when there is a hardware fault (additionally, an LED may be lit on a PSU, drawer, DDIC, fan module, or IO module indicating the part at fault)

• Logical Status: Amber when there is a change of status or fault from something other than the storage system itself (this is usually associated with a disk drive as indicated by its own fault LED)

• Drawer 1 Fault: Amber when a drive, cable, or sideplane fault has occurred in drawer 1

• Drawer 2 Fault: Amber when a drive, cable, or sideplane fault has occurred in drawer 2

NOTE:

Both drawer fault LEDs (and all contained DDIC LEDs) will flash when the storage system indicator is set to On in Storage Client.

About the SCv2080 Storage System

9

Page 9
Image 9
Dell E11J001 owner manual Item